Your browser doesn't support javascript.
loading
節目: 20 | 50 | 100
结果 1 - 20 de 2.086
过滤器
1.
J. bras. nefrol ; 46(2): e2024PO02, Apr.-June 2024.
文章 在 英语 | LILACS-Express | LILACS | ID: biblio-1550492

摘要

ABSTRACT The desperate attempt to improve mortality, morbidity, quality of life and patient-reported outcomes in patients on hemodialysis has led to multiple attempts to improve the different modes, frequencies, and durations of dialysis sessions in the last few decades. Nothing has been more appealing than the combination of diffusion and convection in the form of hemodiafiltration. Despite the concrete evidence of better clearance of middle weight molecules and better hemodynamic stability, tangible evidence to support the universal adoption is still at a distance. Survival benefits seen in selected groups who are likely to tolerate hemodiafiltration with better vascular access and with lower comorbid burden, need to be extended to real life dialysis patients who are older than the population studied and have significantly higher comorbid burden. Technical demands of initiation hemodiafiltration, the associated costs, and the incremental benefits targeted, along with patient-reported outcomes, need to be explored further before recommending hemodiafiltration as the mode of choice.


RESUMO A tentativa desesperada de melhorar a mortalidade, morbidade, qualidade de vida e desfechos relatados pelos pacientes em indivíduos em hemodiálise levou a diversas tentativas de aprimorar os diferentes modos, frequências e durações das sessões de diálise nas últimas décadas. Nada foi mais atrativo do que a combinação de difusão e convecção na forma de hemodiafiltração. Apesar das evidências concretas de melhor depuração de moléculas de peso médio e melhor estabilidade hemodinâmica, evidências tangíveis para apoiar a adoção universal ainda estão distantes. Os benefícios de sobrevida observados em grupos selecionados que provavelmente toleram a hemodiafiltração com melhor acesso vascular e com menor carga de comorbidades precisam ser estendidos aos pacientes reais em diálise, que são mais velhos do que a população estudada e apresentam uma carga de comorbidades significativamente maior. As exigências técnicas do início da hemodiafiltração, os custos associados e os benefícios incrementais almejados, juntamente com os desfechos relatados pelos pacientes, precisam ser melhor explorados antes de se recomendar a hemodiafiltração como o modo de escolha.

2.
Rev. Asoc. Odontol. Argent ; 112(1): 1120412, ene.-abr. 2024. ilus, tab
文章 在 西班牙语 | LILACS | ID: biblio-1563272

摘要

Objetivo: Cuando las resinas compuestas son expuestas a procesos de envejecimiento naturales en boca, como es el ciclaje térmico, pueden sufrir un deterioro en sus propiedades ópticas. El objetivo de este estudio fue evaluar la influencia del envejecimiento térmico sobre la estabilidad del color de dos resinas compuestas. Materiales y métodos: Se confeccionaron 120 pas- tillas de resinas compuestas, divididas en dos grupos: uno de resina Spectra Smart (n=60) y otro de resina Filtex Z350 XT (n=60). Estas muestras fueron sometidas a distintos regíme- nes de ciclaje térmico de 0, 10.000, 20.000 y 30.000 ciclos con temperaturas de entre 5 ºC +/- 2 ºC y 55 ºC +/- 2 °C. Los parámetros de color CIE L*a*b* de cada muestra se mi- dieron con un espectrofotómetro antes y después del proceso de envejecimiento. Las diferencias de color se calcularon me- diante la fórmula CIELAB (ΔE). Los datos fueron analizados estadísticamente usando la prueba no paramétrica de Kruskal Wallis y de U-Mann Whitney. Resultados: Los distintos regímenes de termociclado produjeron cambios de color estadísticamente significativos en ambos materiales. El material que tuvo menor estabilidad cromática fue Spectra Smart aunque sin diferencias estadísti- camente significativas. Conclusión: El envejecimiento térmico simulado a tres años afecta la estabilidad de color de las muestras, tanto de las resinas Spectra Smart, como de Filtex Z350 XT, sin alcanzar los valores que clínicamente determinarían la necesidad del reemplazo de las restauraciones (AU)


Aim: When composite resins are exposed to natural ag- ing processes in the mouth, such as the thermal cycling, they may suffer a deterioration in their optical properties. The aim of this study was to evaluate the influence of thermal aging on the color stability of two composite resins. Materials and methods: 120 composite resins tablets were made, divided into two groups: one of Spectra Smart res- in (n=60) and another of Filtex Z350 XT resin (n=60). These were subjected to different thermal cycle regimes of 0, 10,000, 20,000 and 30,000 cycles with temperature between 5 °C +/- 2 °C and 60 °C +/- 2 °C. The CIE L*a*b* color parameters of each sample were measured with a spectrophotometer before and after the aging process. Color differences were calculat- ed using the CIELAB formula (ΔE). The data were statisti- cally analyzed using the non-parametric Kruskal Wallis and U-Mann Whitney tests. Results: The different thermocycling regimes produce statistically significant color changes in both materials. The material that had the least chromatic stability was Spectra Smart, although without statistically significant differences. Conclusion: Simulated 3 year thermal aging affects the color stability of the samples, both Spectra Smart resins and Filtex Z350 XT, without reaching the values that would clini- cally determine the need to replace the restorations (AU)


Subject(s)
Thermodynamics , Composite Resins/chemistry , Hot Temperature/adverse effects , Spectrophotometry/methods , Materials Testing/methods , Data Interpretation, Statistical
3.
Braz. j. biol ; 84: e255235, 2024. tab, graf
文章 在 英语 | LILACS, VETINDEX | ID: biblio-1355897

摘要

Abstract In soybean breeding program, continuous selection pressure on traits response to yield created a genetic bottleneck for improvements of soybean through hybridization breeding technique. Therefore an initiative was taken to developed high yielding soybean variety applying mutation breeding techniques at Plant Breeding Division, Bangladesh Institute of Nuclear Agriculture (BINA), Bangladesh. Locally available popular cultivar BARI Soybean-5 was used as a parent material and subjected to five different doses of Gamma ray using Co60. In respect to seed yield and yield attributing characters, twelve true breed mutants were selected from M4 generation. High values of heritability and genetic advance with high genotypic coefficient of variance (GCV) for plant height, branch number and pod number were considered as favorable attributes for soybean improvement that ensure expected yield. The mutant SBM-18 obtained from 250Gy provided stable yield performance at diversified environments. It provided maximum seed yield of 3056 kg ha-1 with highest number of pods plant-1 (56). The National Seed Board of Bangladesh (NSB) eventually approved SBM-18 and registered it as a new soybean variety named 'Binasoybean-5' for large-scale planting because of its superior stability in various agro-ecological zones and consistent yield performance.


Resumo No programa de melhoramento da soja, a pressão pela seleção contínua para a resposta das características de rendimento criou um gargalo genético para melhorias da soja por meio da técnica de melhoramento por hibridação. Portanto, foi desenvolvida uma variedade de soja de alto rendimento, aplicando técnicas de reprodução por mutação, na Divisão de Melhoramento de Plantas, no Instituto de Agricultura Nuclear de Bangladesh (BINA), em Bangladesh. A cultivar popular BARI Soybean-5, disponível localmente, foi usada como material original e submetida a cinco doses diferentes de raios gama usando Co60. Em relação ao rendimento de sementes e às características de atribuição de rendimento, 12 mutantes genuínos foram selecionados a partir da geração M4. Altos valores de herdabilidade e avanço genético com alto coeficiente de variância genotípico (GCV) para altura da planta, número de ramos e número de vagens foram considerados atributos favoráveis ​​ao melhoramento da soja, garantindo, assim, a produtividade esperada. O mutante SBM-18, obtido a partir de 250Gy, proporcionou desempenho de rendimento estável em ambientes diversificados e produtividade máxima de sementes de 3.056 kg ha-1 com o maior número de vagens planta-1 (56). O Conselho Nacional de Sementes de Bangladesh (NSB) finalmente aprovou o SBM-18 e o registrou como uma nova variedade de soja, chamada 'Binasoybean-5', para plantio em larga escala por causa de sua estabilidade superior em várias zonas agroecológicas e desempenho de rendimento consistente.


Subject(s)
Glycine max/growth & development , Glycine max/genetics , Phenotype , Bangladesh , Plant Breeding , Genotype , Mutation
4.
Braz. j. biol ; 84: e254010, 2024. tab, graf
文章 在 英语 | LILACS, VETINDEX | ID: biblio-1345561

摘要

Abstract The impact of fish oil concentration on the oxidative stability of microcapsules through the spray drying process using chitosan and maltodextrin as wall material was studied. Emulsions were prepared with different Tuna fish oil (TFO) content (TFO-10%, TFO20%, TF030% TF0-40%) while wall material concentration was kept constant. Microencapsulated powder resulting from emulsion prepared with high fish oil load have high moisture content, wettability, total oil and low encapsulation efficiency, hygroscopicity and bulk tapped density. Oxidative stability was evaluated periodically by placing microcapsules at room temperature. Microcapsules prepared with TFO-10% presented high oxidative stability in terms of peroxide value (2.94±0.04) and anisidine value (1.54±0.02) after 30 days of storage. It was concluded that optimal amounts of fish oil for microencapsulation are 10% and 20% using chitosan and maltodextrin that extended its shelf life during study period.


Resumo Foi estudado o impacto da concentração de óleo de peixe na estabilidade oxidativa de microcápsulas por meio do processo de secagem por atomização, utilizando quitosana e maltodextrina como material de parede. As emulsões foram preparadas com diferentes teores de óleo de atum (TFO) (TFO-10%, TFO20%, TF030% TF0-40%), enquanto a concentração de material de parede foi mantida constante. O pó microencapsulado resultante da emulsão preparada com alta carga de óleo de peixe tem alto teor de umidade, molhabilidade e óleo total e baixa eficiência de encapsulação, higroscopicidade e densidade extraída a granel. A estabilidade oxidativa foi avaliada periodicamente colocando microcápsulas à temperatura ambiente. As microcápsulas preparadas com TFO-10% apresentaram alta estabilidade oxidativa em termos de valor de peróxido (2,94 ± 0,04) e valor de anisidina (1,54 ± 0,02) após 30 dias de armazenamento. Concluiu-se que as quantidades ideais de óleo de peixe para microencapsulação são de 10% e 20% usando quitosana e maltodextrina que prolongaram sua vida útil durante o período de estudo.


Subject(s)
Animals , Fish Oils , Chitosan , Powders , Tuna , Oxidative Stress
5.
Braz. j. biol ; 842024.
文章 在 英语 | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469256

摘要

Abstract The impact of fish oil concentration on the oxidative stability of microcapsules through the spray drying process using chitosan and maltodextrin as wall material was studied. Emulsions were prepared with different Tuna fish oil (TFO) content (TFO-10%, TFO20%, TF030% TF0-40%) while wall material concentration was kept constant. Microencapsulated powder resulting from emulsion prepared with high fish oil load have high moisture content, wettability, total oil and low encapsulation efficiency, hygroscopicity and bulk tapped density. Oxidative stability was evaluated periodically by placing microcapsules at room temperature. Microcapsules prepared with TFO-10% presented high oxidative stability in terms of peroxide value (2.94±0.04) and anisidine value (1.54±0.02) after 30 days of storage. It was concluded that optimal amounts of fish oil for microencapsulation are 10% and 20% using chitosan and maltodextrin that extended its shelf life during study period.


Resumo Foi estudado o impacto da concentração de óleo de peixe na estabilidade oxidativa de microcápsulas por meio do processo de secagem por atomização, utilizando quitosana e maltodextrina como material de parede. As emulsões foram preparadas com diferentes teores de óleo de atum (TFO) (TFO-10%, TFO20%, TF030% TF0-40%), enquanto a concentração de material de parede foi mantida constante. O pó microencapsulado resultante da emulsão preparada com alta carga de óleo de peixe tem alto teor de umidade, molhabilidade e óleo total e baixa eficiência de encapsulação, higroscopicidade e densidade extraída a granel. A estabilidade oxidativa foi avaliada periodicamente colocando microcápsulas à temperatura ambiente. As microcápsulas preparadas com TFO-10% apresentaram alta estabilidade oxidativa em termos de valor de peróxido (2,94 ± 0,04) e valor de anisidina (1,54 ± 0,02) após 30 dias de armazenamento. Concluiu-se que as quantidades ideais de óleo de peixe para microencapsulação são de 10% e 20% usando quitosana e maltodextrina que prolongaram sua vida útil durante o período de estudo.

6.
Braz. j. biol ; 842024.
文章 在 英语 | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469302

摘要

Abstract In soybean breeding program, continuous selection pressure on traits response to yield created a genetic bottleneck for improvements of soybean through hybridization breeding technique. Therefore an initiative was taken to developed high yielding soybean variety applying mutation breeding techniques at Plant Breeding Division, Bangladesh Institute of Nuclear Agriculture (BINA), Bangladesh. Locally available popular cultivar BARI Soybean-5 was used as a parent material and subjected to five different doses of Gamma ray using Co60. In respect to seed yield and yield attributing characters, twelve true breed mutants were selected from M4 generation. High values of heritability and genetic advance with high genotypic coefficient of variance (GCV) for plant height, branch number and pod number were considered as favorable attributes for soybean improvement that ensure expected yield. The mutant SBM-18 obtained from 250Gy provided stable yield performance at diversified environments. It provided maximum seed yield of 3056 kg ha-1 with highest number of pods plant-1 (56). The National Seed Board of Bangladesh (NSB) eventually approved SBM-18 and registered it as a new soybean variety named Binasoybean-5 for large-scale planting because of its superior stability in various agro-ecological zones and consistent yield performance.


Resumo No programa de melhoramento da soja, a pressão pela seleção contínua para a resposta das características de rendimento criou um gargalo genético para melhorias da soja por meio da técnica de melhoramento por hibridação. Portanto, foi desenvolvida uma variedade de soja de alto rendimento, aplicando técnicas de reprodução por mutação, na Divisão de Melhoramento de Plantas, no Instituto de Agricultura Nuclear de Bangladesh (BINA), em Bangladesh. A cultivar popular BARI Soybean-5, disponível localmente, foi usada como material original e submetida a cinco doses diferentes de raios gama usando Co60. Em relação ao rendimento de sementes e às características de atribuição de rendimento, 12 mutantes genuínos foram selecionados a partir da geração M4. Altos valores de herdabilidade e avanço genético com alto coeficiente de variância genotípico (GCV) para altura da planta, número de ramos e número de vagens foram considerados atributos favoráveis ao melhoramento da soja, garantindo, assim, a produtividade esperada. O mutante SBM-18, obtido a partir de 250Gy, proporcionou desempenho de rendimento estável em ambientes diversificados e produtividade máxima de sementes de 3.056 kg ha-1 com o maior número de vagens planta-1 (56). O Conselho Nacional de Sementes de Bangladesh (NSB) finalmente aprovou o SBM-18 e o registrou como uma nova variedade de soja, chamada Binasoybean-5, para plantio em larga escala por causa de sua estabilidade superior em várias zonas agroecológicas e desempenho de rendimento consistente.

7.
Chinese Journal of Biologicals ; (12): 129-137, 2024.
文章 在 中文 | WPRIM | ID: wpr-1006850

摘要

@#Objective To evaluate the stability of polyribosylribitol phosphate(PRP),the basic structure of capsular polysaccharide of Haemophilus influenzae type b(Hib),in the preparation of Hib conjugate vaccine.Methods The structures of the prepared Hib polysaccharides,polysaccharide derivatives and protein-conjugated polysaccharides were analyzed by nuclear magnetic resonance spectroscopy(NMR).Results The detection results of the prepared Hib polysaccharides,polysaccharide derivatives and protein-conjugated polysaccharides all met the requirements of relevant standards of Chinese Pharmacopoeia(VolumeⅢ,2020 edition),and the NMR spectra showed no significant change.Conclusion The basic structure PRP of the main carbohydrate antigen of Hib conjugate vaccine had no change during the vaccine manufacturing.

8.
文章 在 中文 | WPRIM | ID: wpr-1007287

摘要

ObjectiveTo investigate the clinical efficacy of lumbar core muscle stability training combined with kinesiology taping technique in the rehabilitation treatment of lumbar disc herniation (LDH). MethodsA total of 99 LDH patients treated in Ningbo Yinzhou No. 2 Hospital from January 2018 to January 2020 were selected and divided into control group (n=49) and observation group (n=50). Kinesiology taping technique was applied to patients in the control group and patients in the observation group were treated with lumbar core muscle stability training combined with kinesiology taping technique, then we compared the therapeutic effect, lumbar function and pain degree, surface electromyography of lumbar extensor muscles, lumbar range of motion, LDH recurrence and skin allergies before and after the treatment between the two groups. ResultsAfter 4 weeks of treatment, compared with those in the control group, in the observation group, the visual analogue scale (VAS) and Oswestry disability index (ODI) scores were significantly lower (P<0.05); the Japanese Orthopaedic Association (JOA) score, mean power frequency of lumbar extensor muscles, integral electromyography value and lumbar function score were significantly higher (P<0.05). During the treatment, there was no significant difference in the incidence of complications between two groups (P>0.05). After 4 weeks of treatment, the observation group had a significantly lower LDH recurrence rate than the control group (P<0.05). ConclusionLumbar core muscle stability training combined with kinesiology taping technique achieves a significantly better therapeutic effect than kinesiology taping technique in the rehabilitation treatment of LDH and can effectively relieve muscle fatigue, help alleviate lumbar spine pain and improve the function of lumbar spine.

9.
文章 在 中文 | WPRIM | ID: wpr-1023040

摘要

Objective:To investigate the value of peripheral blood platelet to gamma-glutamyl transferase ratio (PLT/GGT) in evaluating plaque stability recognized by virtual histology-intravascular ultrasound (VH-IVUS) in patients with coronary heart disease.Methods:This study was a prospective study. A total of 100 patients with coronary heart disease admitted in Zhejiang Veteran Hospital/the Third Affiliated Hospital of Jiaxing University from June 2020 to December 2022 were included. They were divided into vulnerable plaque group (42 cases) and stable plaque group (58 cases) based on the stability of the plaque examined by VH-IVUS. The general data, PLT/GGT and other laboratory indexes were compared between the two groups. The relationship between PLT/GGT and plaque stability in peripheral blood of patients with coronary heart disease and the evaluation value of PLT/GGT on plaque stability were analyzed.Results:The levels of C-reactive protein (CRP) and gamma-glutamyl transferase (GGT) in the vulnerable plaque group were higher than those in the stable plaque group: (8.07 ± 1.85) mg/L vs. (7.23 ± 1.57) mg/L, (72.39 ± 10.85) U/L vs. (67.13 ± 8.57) U/L, and PLT, PLT/GGT levels were lower than those in the stable plaque group: (180.76 ± 11.75) × 10 9/L vs. (187.36 ± 12.47) × 10 9/L, 2.55 ± 0.42 vs. 2.84 ± 0.41, the differences were statistically significant ( P<0.05). Point two column correlation found that the plaque stability recognized by VH-IVUS in patients with coronary heart disease was related to CRP, GGT, PLT, PLT/GGT ( P<0.05). Receiver operating characteristic curve analysis showed that the area under the curve (AUC) for assessing plaque stability using the peripheral blood PLT/GGT in patients with coronary heart disease was 0.71, which had certain evaluation value. Conclusions:The peripheral blood PLT/GGT in patients with coronary heart disease is closely related to the plaque stability recognized by VH-IVUS, and can be used as an effective indicator for evaluating plaque stability in patients.

10.
文章 在 中文 | WPRIM | ID: wpr-1024969

摘要

It is necessary to improve the stability of human serum albumin in response to the complex temperature, light and other conditions during the manufacture and storage. In this paper, the stabilization effect and simple stabilization mechanism of ligands on albumin were described from the perspective of ligand binding to albumin.Through review and comparison, it can be concluded that the common ligand sodium octanoate mainly plays a role in improving thermal stability, and the common ligand N-acetyl-L-tryptophan mainly plays a role in improving antioxidant activity, N-acetyl-L-methionine has better antioxidant and anti-photooxidation than N-acetyl-L-tryptophan.

11.
Neuroscience Bulletin ; (6): 171-181, 2024.
文章 在 英语 | WPRIM | ID: wpr-1010653

摘要

Even though retinal images of objects change their locations following each eye movement, we perceive a stable and continuous world. One possible mechanism by which the brain achieves such visual stability is to construct a craniotopic coordinate by integrating retinal and extraretinal information. There have been several proposals on how this may be done, including eye-position modulation (gain fields) of retinotopic receptive fields (RFs) and craniotopic RFs. In the present study, we investigated coordinate systems used by RFs in the lateral intraparietal (LIP) cortex and frontal eye fields (FEF) and compared the two areas. We mapped the two-dimensional RFs of neurons in detail under two eye fixations and analyzed how the RF of a given neuron changes with eye position to determine its coordinate representation. The same recording and analysis procedures were applied to the two brain areas. We found that, in both areas, RFs were distributed from retinotopic to craniotopic representations. There was no significant difference between the distributions in the LIP and FEF. Only a small fraction of neurons was fully craniotopic, whereas most neurons were between the retinotopic and craniotopic representations. The distributions were strongly biased toward the retinotopic side but with significant craniotopic shifts. These results suggest that there is only weak evidence for craniotopic RFs in the LIP and FEF, and that transformation from retinotopic to craniotopic coordinates in these areas must rely on other factors such as gain fields.


Subject(s)
Animals , Macaca , Visual Fields , Frontal Lobe/physiology , Eye Movements , Brain
12.
Chinese Journal of Biologicals ; (12): 273-279, 2024.
文章 在 中文 | WPRIM | ID: wpr-1016952

摘要

@#Objective To explore the factors affecting the stability of high concentration variable domain of heavy-chain antibody-Fc(VHH-Fc) fusion protein.Methods Three groups of forced degradation experiments,shaking,light and 40℃ high temperature were set up.Differential scanning fluorimetry,dynamic light scattering(DLS) and ultra performance liquid chromatography-mass spectrometry(UPLC-MS) were used to detect the effects of the three forced degradation conditions on the conformational stability,colloidal stability,average hydrodynamic diameter and post-translational modifications of high concentration VHH-Fc fusion protein.Results Under the light condition,the onset temperature of unfolding(T_(onset)),melting temperature(T_m) and aggregation onset temperature(T_(agg)) of high concentration VHH-Fc fusion protein decreased the most,and the oxidation ratio of Met160 and Met266 increased significantly.Under the condition of shaking,the variation of the diffusion interaction parameter(k_D) and the average hydrodynamic diameter was the largest.Conclusion Light can significantly reduce the conformational stability of high concentration VHH-Fc fusion protein and induce methionine oxidation.Shaking has the most significant effect on its colloidal stability and promotes aggregation

13.
文章 在 中文 | WPRIM | ID: wpr-1017302

摘要

Objective:To explore the application and key points of microchannel approaches in resec-tion of cervical intraspinal tumors.Methods:A retrospective analysis was performed on 51 cases of cervi-cal spinal canal tumors from February 2017 to March 2020.Among them,5 cases were located epidural space,6 cases were located epidural and subdural space,and 40 cases were located under the subdural extramedullary space(6 cases were located on the ventral side of the spinal cord).The maximum diameter ranged from 0.5 to 3.0 cm.The clinical manifestations included neck,shoulder or upper limb pain 43 cases,sensory disturbance(numbness)in 22 cases,and limb weakness in 8 cases.The micro-channel keyhole technique was used to expose the tumor,and the tumor was resected microscopically.Results:In this study,35 patients underwent hemilaminectomy,12 patients underwent interlaminar fenestration,2 patients underwent medial 1/4 facetectomy on the basis of hemilaminectomy or interlaminar fenestration.Two tumors were resected through anatomy space(no bone was resected).The degree of tumor resection included total resection in 50 cases and subtotal resection in 1 case.The type of the tumor included 36 schwannomas,12 meningiomas,2 enterogenic cysts and 1 dermoid cyst.There was no infec-tion and cerebrospinal fluid leakage postoperatively.Limb numbness occurred in 7 patients.The average follow-up time was 15 months(3 to 36 months).No deformity such as cervical instability or kyphosis was found.The tumor had no recurrence.Conclusion:The cervical spinal canal is relatively wide,cervical tumors with no more than three segments can be fully exposed by means of microchannel technology.Besides intramedullary or malignant tumors,they can be microsurgically removed.Preservation of the skeletal muscle structure of cervical spine is beneficial to recover the anatomy and function of cervical spine.The electrophysiological monitoring helps to avoid spinal cord or nerve root injury.

14.
文章 在 中文 | WPRIM | ID: wpr-1021566

摘要

BACKGROUND:Studies have shown that poor dynamic postural control may lead to abnormal movement patterns during exercise,which may increase the risk of lower limb joint and anterior cruciate ligament injury.The stability of the body core is the basis of good dynamic postural control. OBJECTIVE:To investigate the effects of core stability training on dynamic postural control and risk of injury in landing movements,and to compare the differences in training effects between genders. METHODS:Thirty-five college students(male=19,female=16)were recruited for 6 weeks of core stability training.The results of the Y balance test,trunk extensor endurance test,trunk flexor endurance test,lateral bridge endurance test,and landing error scoring system were analyzed before and after training. RESULTS AND CONCLUSION:The 6-week core stability training could improve trunk extensor endurance(P<0.001),flexor endurance(P<0.001),and lateral abdominal muscle endurance(P<0.001).Core stability training could improve forward distance(P=0.026),backward inward distance(P<0.001),backward outward distance(P=0.005)and comprehensive score(P<0.001)of Y balance test for male and female college students.Landing error scoring system scores of both male and female college students significantly decreased after 6 weeks of core stability training(P<0.001)while increasing knee(P<0.001)and hip flexion angles(P<0.001),decreasing knee valgus angle(P<0.001)at the moment of touchdown,and could increase the maximum knee flexion angle(P<0.001)and decrease the maximum knee valgus angle(P<0.001).It is concluded that core stability training improves dynamic postural control and improves landing movement patterns,suggesting that it may help reduce the risk of anterior cruciate ligament injury.There are no sex differences in core stability training in terms of increased trunk flexor endurance,lateral bridge muscle group endurance,improved dynamic postural control,and reduced risk of anterior cruciate ligament injury.

15.
文章 在 中文 | WPRIM | ID: wpr-1021716

摘要

BACKGROUND:The threaded conical implant has a good ability to control micro movements and is conducive to immediate loading.However,the effects of double-threaded conical cylindrical implants and conical cylindrical implants on stress distribution and initial stability of implant-bone interface after immediate loading have not been reported. OBJECTIVE:To investigate the impact of double-threaded conical cylindrical implants and conical cylindrical implants on the biological distribution of the implant and the surrounding bone interface during immediate loading in the mandibular molar region. METHODS:(1)Three-dimensional finite element analysis:Conical beam CT scans of the mandible and first molar of a volunteer were used to develop a basal model of the mandible.The double-threaded conical cylindrical implants and conical cylindrical implants were assembled with the mandibular models,and an immediate-load(or delayed implantation)implant model(a total of four models)for the first mandibular molar was established.Loads in four directions(100 N):axial,lingual and buccal 45°,mesial and distal,and buccal and lingual,were applied to the central fossa of each model's crown.Three-dimensional finite element method was used to analyze the implant displacement and the stress distribution at the implant-bone interface.(2)In vitro experiment:With the assistance of the oral implant robot,the double-threaded conical cylindrical implants and conical cylindrical implants were implanted on the same artificial bone pieces,separately,and the immediate load model of immediate implant implantation(or delayed implantation)was established in vitro(a total of four groups of models).Osstell resonance frequency analyzer and SmartPeg sensor were used to measure the implant stability coefficient in four vertical directions:front,rear,left,and right measurements,evaluate the initial stability,and verify the finite element analysis results. RESULTS AND CONCLUSION:(1)The displacement difference between double-threaded conical cylindrical implants and conical cylindrical implants was small when the immediate loading of delayed implantation was applied,but the maximum stress value of conical cylindrical implant-bone interface was greater than that of double-threaded conical cylindrical implant-bone interface.When the immediate loading of immediate implantation was applied,the maximum stress value and the maximum displacement of bone around the implant appeared when the load was applied in mesiodistal direction.The stress value of the conical cylindrical implant reached 298.84 MPa and the maximum displacement was 0.31 mm,both of which were larger than that of the double-threaded conical cylindrical implant.(2)The results of in vitro experiments showed that the stability coefficient of the double-threaded conical cylindrical implant was greater than that of the conical cylindrical implant.(3)Compared with the conical cylindrical implant,the double-threaded conical cylindrical implant has higher initial stability under immediate loading,suggesting that the use of double-threaded conical cylindrical implant should be given priority in clinical immediate loading.

16.
文章 在 中文 | WPRIM | ID: wpr-1021834

摘要

BACKGROUND:Transcranial direct current stimulation(tDCS),as a non-invasive brain stimulation technique,can enhance human muscle strength or improve single-leg landing stability instantly,but no relevant research has demonstrated this yet. OBJECTIVE:To investigate the effect of tDCS on the stability of single-leg landings in human subjects. METHODS:Male undergraduate students from Wuhan Sports University were recruited as study participants.They were divided into two groups,A(n=6)and B(n=5),using a random number table.Group A underwent a sham stimulation session followed by a 3-day washout period,after which they received tDCS.Conversely,Group B received tDCS initially,followed by a 3-day washout period,and subsequently underwent the sham stimulation session.Following the respective stimulation sessions,an immediate single-leg landing test was administered to assess and collect biomechanical parameters.Data resulting from the tDCS intervention were aggregated and analyzed as the experimental group dataset,whereas data stemming from the sham stimulation were consolidated as the control group dataset. RESULTS AND CONCLUSION:Regarding core stability,the tDCS intervention showed a significant interaction with landing height on the maximal trunk flexion angle(P<0.05).A paired comparison of the data showed a significant decrease in the maximum trunk flexion angle following true stimulation compared to sham stimulation at a 30-cm landing height.Additionally,the tDCS intervention had a significant main effect on the maximum trunk lateral bending angle and the mean trunk lateral bending angular velocity(P<0.05).Following true stimulation,there was a significant decrease in the maximum trunk lateral bending angle and the mean trunk lateral bending angular velocity compared to sham stimulation.In terms of lower limb joint stability,the tDCS intervention had a significant main effect on the maximum dynamic ankle valgus angle(P<0.05).This resulted in a significant decrease in the angle following true stimulation compared to sham stimulation.In addition,the tDCS intervention had a significant main effect on the peak muscle activation of the lateral head of the gastrocnemius lateralis(P<0.05).This showed a significant increase after true stimulation compared to sham stimulation.An interaction between the tDCS intervention and landing height was observed for the peak muscle activation of the tibialis anterior(P<0.05).Paired comparison analyses revealed a significant increase in muscle activation after true stimulation specifically at a 60-cm landing height.Regarding center of pressure stability,there were no significant interactions or main effects of the tDCS intervention on the mean lateral displacement,mean lateral displacement velocity,mean anterior-posterior displacement,or mean anterior-posterior displacement velocity at the center of pressure(P>0.05).Furthermore,the tDCS intervention had no significant main effects on any of the center of pressure indicators(P>0.05).In conclusion,tDCS can immediately improve core stability and lower limb joint stability during single-leg landing,making it an effective warm-up technique for improving single-leg landing stability and reducing the risk of lower limb injuries.

17.
文章 在 中文 | WPRIM | ID: wpr-1021930

摘要

BACKGROUND:High ankle sprain is easily missed and leads to ankle dysfunction.Arthroscopy can detect hidden high ankle sprain.Suture-button elastic fixation can restore the biomechanical stability of the distal tibiofibular syndesmosis. OBJECTIVE:To explore the clinical efficacy of Suture-button elastic fixation for high ankle sprain under ankle arthroscopy. METHODS:A retrospective analysis was performed on 40 cases of high ankle sprain patients treated with Suture-button elastic fixation under ankle arthroscopy from August 2019 to August 2021 in the Department of Foot and Ankle Surgery,Wuhan Fourth Hospital.All patients underwent Suture-button elastic fixation.The American Orthopedic Foot and Ankle Society function score,Visual Analog Scale pain score,ankle range of motion,preoperative imaging data,and arthroscopic tibiofibular syndesmosis separation degree were recorded.Meislin criteria were used to evaluate the curative effect and postoperative complications were recorded. RESULTS AND CONCLUSION:(1)40 patients were followed up for 16-48 months after operation.(2)At the last follow-up,American Orthopedic Foot and Ankle Society score was(88.95±6.64 points).Visual Analog Scale score was(1.78±1.23 points).Ankle dorsiflexion range of motion was(33.50±5.79 degrees).Ankle plantarflexion range of motion was(34.50±5.97 degrees).There were statistically significant differences before and after surgery(P<0.05).(3)There was a low positive correlation between the radiographic separation index and the degree of arthroscopic separation(r=0.612,P<0.01).(4)The curative effect was evaluated by Meislin standard,with an excellent and good rate of 95%(38/40).Postoperative ankle joint pain was relieved,and ankle joint activities were significantly improved.(5)During the follow-up period,all patients had no nerve injury or incision infection.In 1 patient,the internal fixation was removed due to skin irritation and squatting sensation after operation.(6)It is concluded that Suture-button elastic fixation for high ankle sprain is effective under ankle arthroscopy in restoring ankle function and maintaining joint stability without the need for secondary removal,and it is worth clinical application.

18.
文章 在 中文 | WPRIM | ID: wpr-1022070

摘要

BACKGROUND:As a unique structure of the cervical spine,the occurrence,development and progression of the uncovertebral joint directly affect the stability and range of motion of the cervical spine,and are also closely related to the pathogenesis of cervical spondylosis.A thorough understanding of the developmental characteristics of the uncovertebral joint is of great significance for the pathogenesis,diagnosis,and treatment of cervical spondylosis. OBJECTIVE:By using imaging and three-dimensional reconstruction technology to measure and observe the cervical uncinate process-related angle in a large sample of different age groups,the aim is to reveal the characteristics of its changes with age and vertebral growth,as well as its relationship with cervical spine stability. METHODS:Using a retrospective research design,we collected 1 447 cases of raw CT imaging data that meet the study requirements for complete cervical spine segments.The raw data were imported into Mimics 21.0 software in DICOM format for post-processing and measurement of angle of uncinate process and sagittal angle of uncinate process.The data were grouped based on gender,age,and side. RESULTS AND CONCLUSION:(1)With the increase of vertebral sequence,the angle of uncinate process increased in a V-shaped shape,and the lowest peak was at C5.The overall population showed a sharp peak with the increase of age,and the peak value mostly occurred in the age range of 30-39 years.(2)The sagittal angle of the uncinate process increased like a fishhook with the increase of the vertebral sequence,and the overall angle of the uncinate process increased with age,and the peak value mostly occurred in the age range of 20-29 years.The uncinate process angle and sagittal angle showed only partial significant differences between sides and genders(P<0.05).(3)It is concluded that the angle of the uncinate process increased with the increase of vertebral sequence in a V-shaped manner.The sagittal angle of the uncinate process increases like a fish hook with increasing vertebral order,while the two angles generally peak with increasing age.The angle of the uncinate process is about 131°,which may be closely related to the stability of the cervical spine,while the sagittal angle of the uncinate process is about 14°,and its function may play a certain role in limiting the excessive rotation of the cervical spine.

19.
文章 在 中文 | WPRIM | ID: wpr-1022730

摘要

Objective To assess the tear film stability and morphological characteristics of the tarsal gland in myopic children.Methods In this prospective descriptive study,myopic children who performed refractive examinations in the Pediatric Ophthalmology & Refraction Clinic,Jinan Mingshui Eye Hospital from November 2021 to November 2022 were in-cluded.An Ocular Surface Disease Index(OSDI)questionnaire survey was carried out;tear meniscus height(TMH),non-invasive first breakup time(NIf-BUT)and images of the tarsal glands were obtained by OCULUS Keratograph 5M compre-hensive ocular surface analyzer.In addition,the atrophy and tortuosity of tarsal glands were scored to analyze the tear film stability and clinical characteristics of tarsal glands in myopic children.Results A total of 48 myopic children(91 eyes)aged from 7 to 16(10.25±2.23)years were recruited,including 27 males(56.25%)and 21 females(43.75%).The aver-age TMH was(0.19±0.04)mm(95%CI:0.18-0.19)and the average NIf-BUT was(5.40±2.62)s(95%CI:4.90-5.94);the TMH was positively correlated with NIf-BUT(r=0.223,P=0.034).The tarsal gland atrophy score was 1(0,1).The tortuosity score of the upper and lower tarsal gland was 0(0,1)and 0(0,0),respectively,with a statistically significant difference(Z=3.692,P<0.001).In all subjects,49 eyes(53.85%)had tarsal gland atrophy,and 37 eyes(40.66%)had tarsal gland tortuosity.There were significant differences in TMH and NIf-BUT between children aged<12 years and children aged ≥12 years(both P<0.05).There was a significant difference in TMH between children with an OSDI score<13 and children with an OSDI score ≥ 13(t=2.305,P=0.026).There was a significant difference in NIf-BUT between mild and moderate myopia children(t=2.300,P=0.024);the spherical equivalent was positively correlated with NIf-BUT(r=0.283,P=0.023).Conclusion Children with mild to moderate myopia show low tear film stability and a certain proportion of abnormal morphology in tarsal glands.In addition to the refractive status of children,attention should also be paid to ocular surface health in the refraction clinic.

20.
文章 在 中文 | WPRIM | ID: wpr-1029895

摘要

Objective:To assess the applicability of fully automatic pipeline automated testing for internal quality control (automated quality control).Methods:Stability, assay efficiency and implementation costs of 18 biochemical tests, 5 immunoturbidimetric tests and 11 chemical illuminescent tests in the Department of Laboratory Medicine of Peking Union Hospital from January 2019 to July 2022 were evaluated using automated quality control implementation methods. The detailed method is as follows: quality control materials for biochemical, immunoturbidimetric and chemiluminescent tests were stored in the refrigerator in the pipeline which was controlled by the intermediate software, and were automatically retrieved and tested as pre-set followed by documenting and storing. The quality control setup for the biochemical tests included refreshing quality control materials daily and weekly,both of which were paralleled for 3 months. The on-line storage stability of quality control materials in the pipeline was evaluated by comparing the coefficients of variation ( CV) of the quality control results between the two patterns. Effect of automated quality control application was evaluated using 6 indicators, including the results′ variation of automatically performed and manually performed quality controls, the out-of-controlled rate, the consumption of quality control materials, the change of staff workload, the impact on the testing time of the first sample, and the failure rate of automated quality control. Results:(1) Storage stability of quality control materials in the pipeline: under the pattern of weekly refresh of the biochemical quality control materials, except for total carbon dioxide (TCO 2) (the CVs of low and high level quality control were respectively 20.24% and 21.82%) and sodium (the CV of low level quality control was 1.51%) that were greater than the allowable variation set by the laboratory, the CVs of the rest tests meet the lab requirements on the allowable variations. (2) The results′ variation of quality control in automatically performed and manually performed control patterns: in the patterns of daily refresh of biochemical quality control materials and weekly refresh of immunoturbidimetric and chemiluminescent quality control materials, the CVs of both low and high levels of quality control were lower in the automatically performed control pattern than that in manually performed pattern for 8 chemiluminescent items of dehydroepiandrosterone sulfate, estradiol, follicle stimulating hormone, luteinizing hormone, serum ferritin, serum folic acid, vitamin B12 and testosterone, 3 immunologic items of complement 3, C reactive protein and immunoglobulin G, and 10 biochemical items of alkaline phosphatase, glucose, calcium, chloride, potassium, lactate dehydrogenase, sodium, urea, low density lipoprotein cholesterol, and adenosine deaminase. The out-of-control rates of biochemistry, immunoturbidimetric and chemiluminescence tests in both quality control patterns conformed with the clinical routine work requirements. (3) Comparison of quality control materials′ consumption: compared with manually performed quality control, weekly consumption of automatically performed chemiluminescent quality control materials decreased 37.5% (from 8 ml to 5 ml); weekly consumption of automatically performed immunoturbidimetric quality control materials decreased 33.3% (from 3 ml to 2 ml). (4)Comparison of staff workload and first sample testing time: compared with manually performed quality control, automatical quality control reduced manual work by about 156 steps per week, and the daily initial testing time was earlier by 15 min on average. The failure rate was 54.5% (37/64) during the early-stage application of the automated quality control which dropped to 10.2% (13/128) in the late-stage. Conclusion:The results of automated quality control detected in the pipeline system meet the quality indicators′ requirements of the laboratory, and the application of automated quality control can improve the quality control, save costs, reduce workload, and improve work efficiency.

搜索明细