文章 在 中文 | WPRIM | ID: wpr-1039536

摘要

【Objective】 To analyze the effect of sample hemolysis on ELISA test results in blood screening laboratory, so as to determine the acceptable tolerance of hemolysis specific to laboratory test items and detection system, and provide reference for the formulation of tolerance standard of sample hemolysis. 【Methods】 Negative and weakly positive (S/CO was about 2) samples with different hemolysis degrees were tested by several commonly used domestic reagents for HBsAg, HIV Ag/Ab, anti-HCV and anti-TP, respectively. The effects of various degrees of hemolysis on the test results of negative and weakly positive samples for each item were analyzed. 【Results】 1) Hemolysis had no effect on the test results (reactive/non-reactive) of negative and weakly positive samples for HBsAg, anti-HCV and anti-TP ELISA items; 2) Hemolysis affected the test results (reactive/non-reactive) of negative and weakly positive samples for HIV Ag/Ab ELISA item. A tolerance of Hb 2 g/L was taken as the acceptable hemolysis degree for HIV Ag/Ab ELISA item. 【Conclusion】 In this study, the acceptable tolerance of hemolytic samples for corresponding test items and detection system in our laboratory were determined. The influence of hemolysis on ELISA test result is related to the reagent, equipment, environment and other factors, therefore the acceptable tolerance of hemolysis should be determined scientifically and reasonably based on the specific evaluation of each laboratory.

2.
文章 在 中文 | WPRIM | ID: wpr-1004375

摘要

【Objective】 To establish scrap indicators for key equipment in blood screening laboratory of blood centers and quantitatively assess the running status of key equipment, so as to provide a scientific method for equipment scrap. 【Methods】 Through the literature review and Delphi method, the scrap indicators of key equipment in blood screening laboratories were established in terms of applicability, economy and advancement of the equipment. The weights of relevant indicators were calculated by analysis hierarchy process (AHP), and the quantitative assessment model of equipment scrap priority was established according to the indicators and its weight. The equipment running data from January 2020 to December 2020 of Laboratory Department were collected and analyzed using the model, and its accuracy was verified based on experience. 【Results】 Thirteen second-level scrap indicators were established, and the weights of the three first-level indexes of applicability, economy and advancement were 0.582, 0.114 and 0.306, respectively. Among the total 30 key equipment, the model score of 4 equipment was less than 0.5, and the running status after manually checking met the scrap standard. 【Conclusion】 The model can accurately assess the scrap priority of key equipment and facilitate the procurement budget and scrapping identification in advance, which can avoid the waste of resources and ensure safe, efficient and orderly laboratory work.

3.
文章 在 中文 | WPRIM | ID: wpr-1004526

摘要

【Objective】 To investigate the unqualified rate of anti-HIV detection of blood screening laboratories in Beijing-Tianjin-Hebei region, and explore the differences in anti-HIV detection ability and influencing factors in each laboratory. 【Methods】 Through filling questionnaires via e-mail, the anti-HIV ELISA unqualified rate and confirmed (WB) positive results (data) from January to December 2018 from 15 blood screening laboratories in Beijing-Tianjin-Hebei region were collected. Our laboratory was responsible for data collection and confirmation, and statistics software SPSS22.0 was used for analysis. 【Results】 1) There was a statistically significant difference among the unqualified rate of anti-HIV ELISA(6.77‱~35.71‱) and confirmed positive rate(0.60‱~3.56‱) in 15 blood screening laboratories in Beijing-Tianjin-Hebei region (P<0.05); 2) There were significant differencse among the ELISA unqualified rate and the confirmed positive rate of 8 reagents for anti-HIV detection(P<0.01), and the sensitivity of the 4th generation detection reagent and the imported reagent was higher than that of the 3rd generation reagent and the domestic reagent. The anti-HIV ELISA unqualified rate of R5 was the highest (19.08‱). 3)There were significant differences in the anti-HIV ELISA unqualified rate of R1, R2, R3, R5 and R7 reagents among different blood station laboratories(P<0.05), and there were no significant differences in the anti-HIV ELISA unqualified rate of R4, R6 and R8 reagents among different blood station laboratories(P>0.05). 4)The unqualified rate of anti-HIV ELISA of laboratories using different regents showed significant differences(P<0.05), except H, J, M. The unqualified rate of imported reagent was significantly higher than that of domestic reagents of laboratories using imported and domestic reagents combinations(P<0.05), except O. 62.5% (5/8) laboratories using domestic 3rd and 4th generation reagent combination showed significant differences in the unqualified rates among different reagents(P<0.05); 5) The positive rate of single-reagent(62.02%~95.45%)in 15 blood screening laboratories showed significant difference(P<0.001), and A was the lowest (62.02%). 【Conclusion】 The anti-HIV detection ability among 15 blood screening laboratories in Beijing-Tianjin-Hebei region is quite different. The application of different reagents is the main factor for the difference, and other factors such as personnel, instruments and test strategies also has a great impact on the detection of anti-HIV. It is still necessary to promote the process of homogenization of blood testing quality among blood screening laboratories in Beijing-Tianjin-Hebei region.

搜索明细