Indicadores de calidad de la atención a neonatos con patologías seleccionadas: estudio piloto / Quality care indicators for neonates with selected pathologies: pilot study
Salud pública Méx
; 61(1): 35-45, ene.-feb. 2019. tab, graf
Article
ي Es
| LILACS
| ID: biblio-1043356
المكتبة المسؤولة:
BR1.1
RESUMEN
Resumen Objetivo:
Desarrollar y pilotar indicadores de calidad de la atención a neonatos con padecimientos relevantes en México (prematuridad, sepsis neonatal, asfixia perinatal e hipoxia intrauterina). Material ymétodos:
Se construyeron indicadores propios a partir de recomendaciones clave de las guías de práctica clínica nacionales e indicadores encontrados en repositorios internacionales. Previa búsqueda, selección y priorización, los indicadores fueron pilotados en dos hospitales. Se analizó la factibilidad de medición, fiabilidad (índice kappa) y utilidad para detectar problemas de calidad.Resultados:
Se seleccionaron y pilotaron 23 indicadores; 12 eran compuestos. Del total, nueve fueron factibles y fiables. La calidad de la información en los hospitales fue diversa y frecuentemente deficiente, limitando tanto la factibilidad como la fiabilidad de los indicadores. Los niveles de cumplimiento identificaron oportunidades de mejora.Conclusiones:
Se propone un set de nueve indicadores válidos, factibles, fiables y útiles para la monitorización de la calidad en la atención a neonatos patológicos.ABSTRACT
Abstract Objective:
Develop and pilot indicators of quality of care to neonates with relevant conditions in Mexico (prematurity, neonatal sepsis, perinatal asphyxia, and intrauterine hypoxia). Materials andmethods:
Own indicators were built based on key recommendations of national clinical practice guidelines and indicators found in international repositories. With previous search, selection and prioritization, the indicators were piloted within two hospitals. The feasibility of measuring, (kappa index) reliability and usefulness was analyzed to detect quality problems.Results:
23 indicators were selected and piloted, 12 are compounds, of the total, nine were feasible and reliable. The quality of the hospital's information was diverse and often poor, limiting both the feasibility and the reliability of the indicators. Improvement opportunities were identified thorough the compliance levels.Conclusions:
A set of nine indicators valid, reliable, feasible and useful indicators is proposed in order to monitor the quality of care of pathological neonates.Key words
النص الكامل:
1
الفهرس:
LILACS
الموضوع الرئيسي:
Asphyxia Neonatorum
/
Quality Indicators, Health Care
/
Fetal Hypoxia
/
Neonatal Sepsis
نوع الدراسة:
Guideline
/
Prognostic_studies
المحددات:
Female
/
Humans
/
Male
/
Newborn
البلد/الأقليم حسب الموضوع:
Mexico
اللغة:
Es
مجلة:
Salud pública Méx
موضوع المجلة:
SAUDE PUBLICA
السنة:
2019
نوع:
Article