Influence of desensitizers agents on the dentin bond strength after one-year water storage
Braz. j. oral sci
; 19: e201602, jan.-dez. 2020. ilus
Article
ي En
| BBO, LILACS
| ID: biblio-1116255
المكتبة المسؤولة:
BR218.1
ABSTRACT
Aim:
Evaluate the effect of adhesives systems combined with desensitizer agents on the microtensile bond strength (µTBS) of a composite resin to dentin.Methods:
Cervical dentin of thirty-two human molars were used to simulate hypersensitivity areas. The teeth were divided into four groups (n=8), according to the type of adhesive system and desensitizer agents. No desensitizer was used in the control (Clearfil SE Bond CS). Two experimental groups were pretreated with either MS Coat Bond (MS) or Biofluorid 12 (BF) immediately prior to bonding with CS. The last group corresponded to Gluma Comfort Bond + Desensitizer (GC) application. After dentin treatments, a composite block was built-up on dentin surface and after 24 hours teeth were serially sectioned to obtain bonded bean specimens. Beams were stored in water for 24 hours or one year. Subsequently, the specimens were submitted to the µTBS test. Data were analyzed by two-way mixed ANOVA and Bonferroni's test (α = 0.05).Results:
At 24 hours, there was no significant difference in µTBS among groups. However, at one year, dentin treated with MS or BF demonstrated significantly lower µTBS of CS to dentin compared to control and GC, which kept their µTBS stable.Conclusion:
The effect of MS and BF desensitizer agents on the µTBS of CS to dentin did not reduce the µTBS at 24 hours, but it decreases significantly after one yearKey words
النص الكامل:
1
الفهرس:
LILACS
الموضوع الرئيسي:
Calcium Fluoride
/
Oxalic Acid
/
Dentin Sensitivity
/
Dentin Desensitizing Agents
اللغة:
En
مجلة:
Braz. j. oral sci
موضوع المجلة:
ODONTOLOGIA
السنة:
2020
نوع:
Article