Your browser doesn't support javascript.
loading
Comparison of samples found positive by anti-HCV screening test with line immunoassay and determination of threshold value
Atalay, Mustafa Altay; Sagiroglu, Pinar; Oskay, Mehtap; Emir, Büsra.
Affiliation
  • Atalay, Mustafa Altay; Erciyes University. School of Medicine. Department of Medical Microbiology. Kayseri. TR
  • Sagiroglu, Pinar; Erciyes University. School of Medicine. Department of Medical Microbiology. Kayseri. TR
  • Oskay, Mehtap; Erciyes University. School of Medicine. Department of Medical Microbiology. Kayseri. TR
  • Emir, Büsra; Izmir Kâtip Celebi University. School of Medicine. Department of Biostatistics. Izmir. TR
Rev. Assoc. Med. Bras. (1992, Impr.) ; 67(10): 1480-1484, Oct. 2021. tab, graf
Article ي En | LILACS | ID: biblio-1351429
المكتبة المسؤولة: BR1.1
ABSTRACT
SUMMARY

OBJECTIVE:

This study aimed to compare the serum samples found reactive (≥1-≤20 signal-to-cutoff ratio) with Elecsys antibodies to hepatitis C virus screening test with innogenetics-line immunassay hepatitis C Virus Score test and to determine the most appropriate threshold value for our country, since positive results close to the cutoff value cause serious problems in routine diagnostic laboratories.

METHODS:

Antibodies to hepatitis C virus-positive samples from 687 different patients were included in the study. Antibodies to hepatitis C virus antibody detection was performed using Elecsys antibodies to hepatitis C virus II kits (Roche Diagnostics, Germany), an electrochemiluminescence method based on the double-antigen sandwich principle, on the Cobas e601 analyzer (Roche Diagnostics) in accordance with the recommendations of the manufacturer. Samples that were initially identified as reactive were studied again. Samples with ≥1-≤20 signal-to-cutoff ratio reagents as a result of retest were included in the study to be validated with the third-Generation Line immunassay kit (innogenetics-line immunassay hepatitis C Virus, Belgium).

RESULTS:

A total of 687 samples with antibodies to hepatitis C virus positive and levels between 1-20 S/Co were found to be 56.1% negative, 14.8% indeterminate, and 29.1% positive by innogenetics-line immunassay hepatitis C Virus confirmation test. When the cases with indeterminate innogenetics-line immunassay hepatitis C Virus test results were accepted as positive, the signal-to-cutoff ratio value for antibodies to hepatitis C virus was determined as 5.8 (95% confidence interval) in distinguishing the innogenetics-line immunassay hepatitis C Virus negative and positive groups.

CONCLUSION:

It was concluded that with further studies on this subject, each country should determine the most appropriate S/Co value for its population, and thus it would be beneficial to reduce the problems such as test repetition and cost increase.
الموضوعات
Key words

النص الكامل: 1 الفهرس: LILACS الموضوع الرئيسي: Hepatitis C / Hepatitis C Antibodies نوع الدراسة: Diagnostic_studies / Guideline / Prognostic_studies / Screening_studies المحددات: Humans اللغة: En مجلة: Rev. Assoc. Med. Bras. (1992, Impr.) موضوع المجلة: Educa‡Æo em Sa£de / GestÆo do Conhecimento para a Pesquisa em Sa£de / MEDICINA السنة: 2021 نوع: Article

النص الكامل: 1 الفهرس: LILACS الموضوع الرئيسي: Hepatitis C / Hepatitis C Antibodies نوع الدراسة: Diagnostic_studies / Guideline / Prognostic_studies / Screening_studies المحددات: Humans اللغة: En مجلة: Rev. Assoc. Med. Bras. (1992, Impr.) موضوع المجلة: Educa‡Æo em Sa£de / GestÆo do Conhecimento para a Pesquisa em Sa£de / MEDICINA السنة: 2021 نوع: Article