An in-house PPA-ELISA was compared to a commercial ELISA using a panel of 108 serum samples. In relation to commercial test, in-house assay presented 100 percent of sensitivity and 83.5 percent of specificity and a high concordance (kappa> 0.5), which demonstrates that the in-house assay is a valuable tool for use in developing countries.
RESUMO
Um teste ELISA in-house foi comparado a um teste comercial utilizando um painel de 108 soros. Em relação ao teste comercial, o ensaio in-house apresentou sensibilidade de 100 por cento, especificidade de 83,5 por cento e alta concordância (kapa>0,5), o que demonstra seu valor para uso em países em desenvolvimento.