Variação da temperatura intra-câmara pulpar em função da ativação com LED de géis clareadores de uso ambulatorial / Variation of temperature in pulp chamber due to LED bleaching gels activation
Nahsan, Flavia Pardo Salata; Wang, Linda; Kegler, Eugênio Pangrazio; Dávalos, Patricia Escobar; Mondelli, Rafael Francisco Lia.
Affiliation
  • Nahsan, Flavia Pardo Salata; Universidade Federal de Sergipe. Sergipe. BR
  • Wang, Linda; Universidade de São Paulo. Bauru. BR
  • Kegler, Eugênio Pangrazio; s.af
  • Dávalos, Patricia Escobar; s.af
  • Mondelli, Rafael Francisco Lia; Universidade de São Paulo. Bauru. BR
Full dent. sci ; 6(24): 526-530, set.2015. ilus, tab, graf
Article ي Pt | LILACS | ID: lil-777674
المكتبة المسؤولة: BR1264.1
RESUMO
Este estudo avaliou o efeito da aplicação de diferentes géis clareadores na temperatura intra-câmara pulpar no clareamento fotoativado em consultório. Preencheu-se a câmara pulpar de um incisivo com pasta térmica e um sensor digital Termopar, e a raiz submersa em água a 37°C. Avaliaram-se 6 grupos G1- SG sem gel; PH G2- peróxido de hidrogênio incolor a 35%; G3- OXB Opalescence Xtra Boost; G4- WHP Whiteness HP; G5- WM Whiteness HP MAXX; G6- LP Lase Peroxide. Para a ativação dos géis empregou-se o aparelho LED por 3 minutos. A aferição da variação de temperatura intra-câmara foi realizada com termômetro digital com termopar tipo K a cada 30 segundos. Os dados foram submetidos à ANOVA a dois critérios e teste de Tukey. Os resultados foram 60 s - O grupo G2 (38° C) apresentou menor valor que os demais; 90 s - G2 (38,8°C) < G6 (39,6°C), G3 (39,8°C); 120 s - G2 (38,8°C) < G3 (40°C), G4 (39,6°C), G5 (39,8°C), G6 (40°C); 150 s - G2 (39°C) < G1 (39,8°C) G3, G4, G5, G6 (40°C); 180 s. A média final obtida foi G2 (38,72°C) < G5 (39,16°C) < G1 (39,27°C) < G4 (39,30°C) < G6 (39,33°C) < G3 (39,47°C). O gel incolor não promoveu aumento significante na temperatura intrapulpar; géis clareadores com corante vermelho e verde aceleram este aumento quando ativados por luz LED azul de alta densidade de energia...
ABSTRACT
This study has evaluated the effect of different dental bleaching gels over the pulp chamber temperature during in-office photoactivated dental bleaching. The empty pulp chamber of an incisor was filled with a heat sink compound and a thin digital K-type thermocouple, immersed in distilled water at 37°C. Six groups were evaluated G1 with no gel; G2 colorless gel; G3- OXB Opalescence Xtra Boost; G4- WHP Whiteness HP; G5- WM Whiteness HP MAXX; G6- LP Lase Peroxide. The gel light activation was made using LED, during 3 consecutive minutes. The intra-pulpal temperature was measured using a digital thin K-type thermocouple K at every 30 seconds. Data were submitted to ANOVA and TukeyÆs test. Results showed 60 s -G2 (38°C) showed lower value than the others; 90s -G2 (38.8°C) < G6 (39.6°C), G3 (39.8°C); 120 s - G2 (38.8°C) < G3 (40°C), G4 (39.6°C), G5 (39.8°C), G6 (40°C); 150 s - G2 (39°C) < G1 (39.8°C) G3, G4, G5, G6 (40°C); 180 s. The final mean obtained was G2 (38,72°C) < G5 (39,16°C) < G1 (39,27°C) < G4 (39,30°C) < G6 (39,33°C) < G3 (39,47°C). The colorless gel did not provided significant increase in the pulp chamber temperature; bleaching gels with red and green dyes accelerate this increase in temperature when activated by blue LED light with high energy density...