Your browser doesn't support javascript.
loading
Effect of dynamic lung compliance-guided individual positive end-expiratory pressure titration on pulmonary function in elderly patients undergoing laparoscopic colorectal cancer surgery / 临床麻醉学杂志
Article ي Zh | WPRIM | ID: wpr-1019176
المكتبة المسؤولة: WPRO
ABSTRACT
Objective To investigate the effects of dynamic lung compliance(Cdyn)-guided indi-vidual positive end-expiratory pressure(PEEP)titration on pulmonary function in elderly patients undergoing laparoscopic colorectal cancer surgery.Methods Sixty-eight elderly patients were selected for laparoscopic radical resection of colorectal cancer,37 males and 31 females,aged 65-79 years,BMI<30 kg/m2,ASA physical status Ⅱ or Ⅲ.The patients were divided into two groups using the random number table

method:

individualized PEEP group(group P)and control group(group C),34 patients in each group.In group P,the patients received recruitment maneuvers and PEEP titration test at immediately after intubation,immediately after establishing pneumoperitoneum-Trendelenburg position and immediately after pneumoperitoneum.The patients in group C received PEEP 5 cmH2 O during procedure.The three best titra-tion PEEP and the actual tidal volume(VT)in group P were also recorded.PaO2,PaCO2,PETCO2 10 mi-nutes after the tracheal intubation(T1),10 minutes(T2)and 1 hour(T3)after establishing pneumoperito-neum-Trendelenburg position,at the end of the surgery but before extubation(T4)were recorded,and the oxygenation index(OI),physiological dead space to tidal volume(Vd/VT),alveolar arterial oxygen differ-ence(A-aDO2),driving pressure,and Cdyn were calculated.Concentrations of interleukin-8(IL-8),tumor necrosis factor-α(TNF-α),Clara cell secretoyr protein(CC16)and lung alveolar surface active sub-stances-D(SP-D)in the serum samples were determined by ELISA before anesthesia induction(T0)and 10 minutes after extubation(T5).Postoperative pulmonary complications(PPCs)were also recordrd.Results The individualized PEEP of Cdyn?guided PEEP titration was 4 cmH2O. Compared with group C, the PaO2 and OI in group C were significantly increased at T4, the Cdyn was significantly increased at T1,T3, and T4, the driving pressure was significantly decreased at T1 -T4, the serum concentration of CC16 was significantly decreased at T5 ( P < 0. 05). There were no significant differences in PaCO2, PET CO2,A?aDO2, and Vd/ VT between the two groups. There was no severe PPCs in the two groups. Conclusion Pressure?controlled ventilation modes combined with Cdyn?guide PEEP titration can increase the Cdyn, reduce thedriving pressure, and improve OI at the end of the operation, reduce the concentrations of CC16 at postop?eration, improve pulmonary function in elderly patients undergoing laparoscopic colorectal cancer surgery.
Key words
النص الكامل: 1 الفهرس: WPRIM اللغة: Zh مجلة: The Journal of Clinical Anesthesiology السنة: 2024 نوع: Article
النص الكامل: 1 الفهرس: WPRIM اللغة: Zh مجلة: The Journal of Clinical Anesthesiology السنة: 2024 نوع: Article