Your browser doesn't support javascript.
loading
Estimation of Intraocular Lens Power Calculation after Myopic Corneal Refractive Surgery: Using Corneal Height in Anterior Segment Optical Coherence Tomography
Article ي En | WPRIM | ID: wpr-134568
المكتبة المسؤولة: WPRO
ABSTRACT
PURPOSE: To investigate the feasibility of estimating effective lens position (ELP) and calculating intraocular lens power using corneal height (CH), as measured using anterior segment optical coherence tomography (AS-OCT), in patients who have undergone corneal refractive surgery. METHODS: This study included 23 patients (30 eyes) who have undergone myopic corneal refractive surgery and subsequent successful cataract surgery. The CH was measured with AS-OCT, and the measured ELP (ELP(m)) was calculated. Intraocular lens power, which could achieve actual emmetropia (P(real)), was determined with medical records. Estimated ELP (ELP(est)) was back-calculated using P(real), axial length, and keratometric value through the SRK/T formula. After searching the best-fit regression formula between ELP(m) and ELP(est), converted ELP and intraocular lens power (ELP(conv), P(conv)) were obtained and then compared to ELP(est) and P(real), respectively. The proportion of eyes within a defined error was investigated. RESULTS: Mean CH, ELP(est), and ELP(m) were 3.71 +/- 0.23, 7.74 +/- 1.09, 5.78 +/- 0.26 mm, respectively. The ELP(m) and ELP(est) were linearly correlated (ELP(est) = 1.841 x ELP(m) - 2.018, p = 0.023, R = 0.410) and ELP(conv) and P(conv) agreed well with ELP(est) and P(real), respectively. Eyes within +/-0.5, +/-1.0, +/-1.5, and +/-2.0 diopters of the calculated P(conv), were 23.3%, 66.6%, 83.3%, and 100.0%, respectively. CONCLUSIONS: Intraocular lens power calculation using CH measured with AS-OCT shows comparable accuracy to several conventional methods in eyes following corneal refractive surgery.
الموضوعات
Key words
النص الكامل: 1 الفهرس: WPRIM الموضوع الرئيسي: Retrospective Studies / Cornea / Tomography, Optical / Tomography, Optical Coherence / Refractive Surgical Procedures / Axial Length, Eye / Lenses, Intraocular نوع الدراسة: Observational_studies المحددات: Humans / Male اللغة: En مجلة: Korean Journal of Ophthalmology السنة: 2015 نوع: Article
النص الكامل: 1 الفهرس: WPRIM الموضوع الرئيسي: Retrospective Studies / Cornea / Tomography, Optical / Tomography, Optical Coherence / Refractive Surgical Procedures / Axial Length, Eye / Lenses, Intraocular نوع الدراسة: Observational_studies المحددات: Humans / Male اللغة: En مجلة: Korean Journal of Ophthalmology السنة: 2015 نوع: Article