Your browser doesn't support javascript.
loading
Evaluation on the efficacy and safety of calcium metaphosphate coated fixture
Article ي En | WPRIM | ID: wpr-14712
المكتبة المسؤولة: WPRO
ABSTRACT
PURPOSE: The purpose of this study was to assess the difference in efficacy between calcium metaphosphate (CMP)-coated implant fixtures and conventional resorbable blasted media (RBM) processed implant fixtures. MATERIALS AND METHODS: This study targeted 50 implants from 44 patients who visited Dankook University Dental Hospital. Implantations were done separately for RBM treated and CMP-coated implants, although their design was the same. Calcium metaphosphate has a quicker biodegradation process through hydrolysis compared to other phosphate calcium groups. For the first year of the implantation, the resorption volume of marginal bone analyzed via radiography and perio-test value were measured, under the check plan. Their analyses were composed of a non-inferiority trials test. A 95% level of reliability was used. RESULTS: In the comparative analysis of the resorption volume of marginal bone and the perio-test value, no statistically significant difference was found between the CMP-coated implants and RBM implants. CONCLUSION: One year after the implant placement, CMP-coated implants were found not to be inferior to the conventional RBM implants.
الموضوعات
Key words
النص الكامل: 1 الفهرس: WPRIM الموضوع الرئيسي: Calcium / Hydrolysis المحددات: Humans اللغة: En مجلة: The Journal of Advanced Prosthodontics السنة: 2013 نوع: Article
النص الكامل: 1 الفهرس: WPRIM الموضوع الرئيسي: Calcium / Hydrolysis المحددات: Humans اللغة: En مجلة: The Journal of Advanced Prosthodontics السنة: 2013 نوع: Article