Dual-Energy CT in the Assessment of Mediastinal Lymph Nodes: Comparative Study of Virtual Non-Contrast and True Non-Contrast Images
Korean j. radiol ; Korean j. radiol;: 532-539, 2013.
Article ي En | WPRIM | ID: wpr-208251
المكتبة المسؤولة: WPRO
ABSTRACT
OBJECTIVE: To evaluate the reliability of virtual non-contrast (VNC) images reconstructed from contrast-enhanced, dual-energy scans compared with true non-contrast (TNC) images in the assessment of high CT attenuation or calcification of mediastinal lymph nodes. MATERIALS AND METHODS: A total of 112 mediastinal nodes from 45 patients who underwent non-contrast and dual-energy contrast-enhanced scans were analyzed. Node attenuation in TNC and VNC images was compared both objectively, using computed tomography (CT) attenuation, and subjectively, via visual scoring (0, attenuation the aorta; 2, calcification). The relationship among attenuation difference between TNC and VNC images, CT attenuation in TNC images, and net contrast enhancement (NCE) was analyzed. RESULTS: CT attenuation in TNC and VNC images showed moderate agreement (intraclass correlation coefficient, 0.612). The mean absolute difference was 7.8 +/- 7.6 Hounsfield unit (HU) (range, 0-36 HU), and the absolute difference was equal to or less than 10 HU in 65.2% of cases (73/112). Visual scores in TNC and VNC images showed fair agreement (kappa value, 0.335). Five of 16 nodes (31.3%) which showed score 1 (n = 15) or 2 (n = 1) in TNC images demonstrated score 1 in VNC images. The TNC-VNC attenuation difference showed a moderate positive correlation with CT attenuation in TNC images (partial correlation coefficient [PCC] adjusted by NCE: 0.455) and a weak negative correlation with NCE (PCC adjusted by CT attenuation in TNC: -0.245). CONCLUSION: VNC images may be useful in the evaluation of mediastinal lymph nodes by providing additional information of high CT attenuation of nodes, although it is underestimated compared with TNC images.
الموضوعات
Key words
النص الكامل: 1 الفهرس: WPRIM الموضوع الرئيسي: Image Processing, Computer-Assisted / Calcinosis / Tomography, X-Ray Computed / Reproducibility of Results / Sensitivity and Specificity / Contrast Media / Lymph Nodes / Mediastinum نوع الدراسة: Diagnostic_studies المحددات: Adult / Aged / Aged80 / Female / Humans / Male اللغة: En مجلة: Korean j. radiol السنة: 2013 نوع: Article
النص الكامل: 1 الفهرس: WPRIM الموضوع الرئيسي: Image Processing, Computer-Assisted / Calcinosis / Tomography, X-Ray Computed / Reproducibility of Results / Sensitivity and Specificity / Contrast Media / Lymph Nodes / Mediastinum نوع الدراسة: Diagnostic_studies المحددات: Adult / Aged / Aged80 / Female / Humans / Male اللغة: En مجلة: Korean j. radiol السنة: 2013 نوع: Article