ABSTRACT
Objective To establish a new chemiluminescence method for determination of resorcinol in wastewater. Methods In media of acidchemiluminescence reaction of resorcinol with ceriumⅣ in the presence of Tween 40 as enhancer was investigated. A new chemiluminescence method for determination of resorcinol with flow injection technique was developed. Results The linear range for resorcinol was 8.0?10-8~5.0?10-5 mol/L with 6.0?10-8 mol/L detection limit. The relative standard deviation was 3.5% for 5.0?10-6 mol/L resorcinol in 11 parallel measurements. Conclusion This method can used to determine the content of resorcinol in wastewater of laboratory and resorcinol compound solution with satisfactory results.
Key words
النص الكامل: 1 الفهرس: WPRIM اللغة: Zh مجلة: Journal of Environment and Health السنة: 1992 نوع: Article