Right Ventricular Mass Quantification Using Cardiac CT and a Semiautomatic Three-Dimensional Hybrid Segmentation Approach: A Pilot Study
Korean j. radiol
; Korean j. radiol;: 901-911, 2021.
Article
ي En
| WPRIM
| ID: wpr-894756
المكتبة المسؤولة:
WPRO
ABSTRACT
Objective@#To evaluate the technical applicability of a semiautomatic three-dimensional (3D) hybrid CT segmentation method for the quantification of right ventricular mass in patients with cardiovascular disease. @*Materials and Methods@#Cardiac CT (270 cardiac phases) was used to quantify right ventricular mass using a semiautomatic 3D hybrid segmentation method in 195 patients with cardiovascular disease. Data from 270 cardiac phases were divided into subgroups based on the extent of the segmentation error (no error; ≤ 10% error; > 10% error [technical failure]), defined as discontinuous areas in the right ventricular myocardium. The reproducibility of the right ventricular mass quantification was assessed. In patients with no error or 0.1). @*Conclusion@#CT quantification of right ventricular mass using a semiautomatic 3D hybrid segmentation is technically applicable with high reproducibility in most patients with cardiovascular disease.
النص الكامل:
1
الفهرس:
WPRIM
اللغة:
En
مجلة:
Korean j. radiol
السنة:
2021
نوع:
Article