Reverse engineering technique on the evaluation of impression accuracy in angulated implants / 대한치과보철학회지
Article ي En | WPRIM | ID: wpr-895801
المكتبة المسؤولة: WPRO
ABSTRACT
Purpose@#The aim of this study was (1) to compare the reverse engineering technique with other existing measurement methods and (2) to analyze the effect of implant angulations and impression coping types on implant impression accuracy with reverse engineering technique. @*Materials and methods@#Three different master models were fabricated and the distance between the two implant center points in parallel master model was measured with different three methods; digital caliper measurement (Group DC), optical measuring (Group OM), and reverse engineering technique (Group RE). The 90 experimental models were fabricated with three types of impression copings for the three different implant angulation and the angular and distance error rate were calculated. One-way ANOVA was used for comparison among the evaluation methods (P .05). The standard deviations in reverse engineering were much lower than those of digital caliper and optical measurement. Hybrid groups had no significant difference from the pick-up groups in distance error rates (P > .05). @*Conclusion@#The reverse engineering technique demonstrated its potential as an evaluation technique of 3D accuracy of impression techniques.
النص الكامل: 1 الفهرس: WPRIM اللغة: En مجلة: The Journal of Korean Academy of Prosthodontics السنة: 2021 نوع: Article
النص الكامل: 1 الفهرس: WPRIM اللغة: En مجلة: The Journal of Korean Academy of Prosthodontics السنة: 2021 نوع: Article