Your browser doesn't support javascript.
loading
Effect of gallic acid addition on some mechanical properties of self-adhesive resin cements
Oguz Ahmet, Bebek Serra; Sayin Ozel, Gulsum; Mutluay, Mustafa Murat; Tezvergil Mutluay, Arzu.
  • Oguz Ahmet, Bebek Serra; Istanbul Medipol University. School of Dentistry. Department of Prosthodontics. Istanbul. TR
  • Sayin Ozel, Gulsum; Istanbul Medipol University. School of Dentistry. Department of Prosthodontics. Istanbul. TR
  • Mutluay, Mustafa Murat; University of Eastern Finland. Institute of Dentistry. Department of Prosthetic Dentistry. Kuopio. FI
  • Tezvergil Mutluay, Arzu; University of Turku. Institute of Dentistry. Department of Restorative Dentistry and Cariology. Turku. FI
Braz. oral res. (Online) ; 33: e053, 2019. tab, graf
Article in English | LILACS | ID: biblio-1019610
ABSTRACT
Abstract Self-adhesive resin cements (RCs) activate matrix metalloproteinase (MMP) and cathepsin-related collagen degradation, and gallic acid (GA) inhibits the activity of both MMPs and cysteine cathepsins. The purpose of this study was to evaluate the setting time, biaxial flexural strength, and Vickers hardness of self-adhesive RCs after the addition of two different concentrations of GA. RelyX U200 (3M ESPE) and Panavia SA (Kuraray) were modified with 0.5 and 1 wt% GA. The setting time of five samples in each RC group was assessed using a thermocouple apparatus as described in the ISO 4049 test. Biaxial flexure strength was measured using a universal testing machine until failure. Vickers hardness was measured with three randomized indentations on the surface of each resin disc. RCs without GA were used as control. Data were analyzed using a one-way analysis of variance and Tukey's HSD test (α = 0.05). The setting times ranged from 2.4 to 4.6 min for RelyX and from 4.9 to 6.0 min for Panavia. The biaxial flexure strength ranged from 76.5 to 109.7 MPa for RelyX and from 73.3 to 108.2 MPa for Panavia. Vickers hardness values ranged from 41.6 to 58.6 for RelyX and 27.2 to 33.6 for Panavia. The addition of 0.5 and 1 wt% GA to improve durability of resin-dentin bonds had no adverse effects on setting time, whereas the biaxial flexure strength and Vickers hardness values for the tested materials were significantly reduced.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Resin Cements / Gallic Acid Type of study: Controlled clinical trial / Evaluation studies Language: English Journal: Braz. oral res. (Online) Journal subject: Dentistry Year: 2019 Type: Article Affiliation country: Finland / Turkey Institution/Affiliation country: Istanbul Medipol University/TR / University of Eastern Finland/FI / University of Turku/FI

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Resin Cements / Gallic Acid Type of study: Controlled clinical trial / Evaluation studies Language: English Journal: Braz. oral res. (Online) Journal subject: Dentistry Year: 2019 Type: Article Affiliation country: Finland / Turkey Institution/Affiliation country: Istanbul Medipol University/TR / University of Eastern Finland/FI / University of Turku/FI