Your browser doesn't support javascript.
loading
Comparación entre los sistemas manual de limas de acero inoxidable y el rotatorio de limas de níquel titanio, en la conformación de conductos radiculares curvos in vitro / Comparison between the manual system of stainless steel files and the rotating system of nickel titanium files in the conformation of curved radicular ducts in vitro
Quiroz-Málaga, Johanna Elizabeth; Ramos-Torres, Wilfredo Fidel; Aguirre-Siancas, Elias Ernesto.
  • Quiroz-Málaga, Johanna Elizabeth; Universidad Católica los Ángeles de Chimbote. PE
  • Ramos-Torres, Wilfredo Fidel; Universidad Católica los Ángeles de Chimbote. PE
  • Aguirre-Siancas, Elias Ernesto; Universidad Científica del Sur. PE
Odontol. vital ; (31): 31-36, jul.-dic. 2019. tab, graf
Article in Spanish | LILACS, BBO | ID: biblio-1091425
RESUMEN
Resumen

Introducción:

Estudio experimental donde se procuró comparar el efecto del sistema manual y del rotatorio sobre la conformación de conductos curvos.

Metodología:

Una muestra de 40 raíces mesiales de primeras molares inferiores fue aleatorizada en dos grupos iguales grupos sistema manual de limas K y sistema rotatorio FGK Race®. Se comparó el radio de la curvatura final vs. el inicial mediante el programa Autocat 2015. Se empleó la prueba t con significancia de 0,05.

Resultados:

El radio de la curvatura varió de manera significativa, tanto para sistema manual como para el rotatorio FGK Race® (p=0,0001 y p=0,0013, respectivamente). Además, el sistema manual produjo mayor variación en el radio de la curvatura al compararlo con el sistema rotatorio 2,23 mm vs. 1,27 mm respectivamente; p=0,13.

Conclusiones:

Ambos sistemas produjeron modificación en la conformación de los conductos mesiales; sin embargo, en la comparación entre ambos dichas diferencias no fueron significativas.
ABSTRACT
Abstract

Introduction:

An experimental study was carried out to compare the effect of the manual system and the rotary system on the conformation of curved conduits.

Methodology:

A sample of 40 mesial roots of lower first molars was randomized into two equal groups group manual system of K-files and group rotary system FGK Race®. The radius of the final curvature vs. the initial curvature was compared using the Autocat 2015 program. The t-test with a significance of 0.05 was used.

Results:

The curvature radius varied significantly for both the manual system and the rotary FGK Race® (p = 0.0001 and p = 0.0013, respectively). In addition, the manual system produced greater variation in the radius of the curvature when compared to the rotary system 2.23mm vs. 1.27mm respectively; p = 0.13.

Conclusion:

Both systems produced modification on the conformation of the conduits of the mesial roots; however, in the comparison between both systems said differences were not significant.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Stainless Steel / Titanium / Dental Instruments / Dental Pulp Cavity / Molar / Nickel Type of study: Controlled clinical trial Language: Spanish Journal: Odontol. vital Journal subject: Odontologia Year: 2019 Type: Article Affiliation country: Peru Institution/Affiliation country: Universidad Católica los Ángeles de Chimbote/PE / Universidad Científica del Sur/PE

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Stainless Steel / Titanium / Dental Instruments / Dental Pulp Cavity / Molar / Nickel Type of study: Controlled clinical trial Language: Spanish Journal: Odontol. vital Journal subject: Odontologia Year: 2019 Type: Article Affiliation country: Peru Institution/Affiliation country: Universidad Católica los Ángeles de Chimbote/PE / Universidad Científica del Sur/PE