Equivalent keratometer reading para cálculo biométrico em córneas assimétricas: série de casos / Equivalent keratometer reading tool for biometric calculation in asymmetric corneas: case series
Ferreira, Diego de Queiroz Tavares; Meireles, Antônio Carlos; Fernandes, Arthur Gustavo; Fernandes, Rodrigo Antônio Brant.
  • Ferreira, Diego de Queiroz Tavares; Ophthal Hospital Especializado. São Paulo. BR
  • Meireles, Antônio Carlos; Ophthal Hospital Especializado. São Paulo. BR
  • Fernandes, Arthur Gustavo; Ophthal Hospital Especializado. São Paulo. BR
  • Fernandes, Rodrigo Antônio Brant; Ophthal Hospital Especializado. São Paulo. BR
Rev. bras. oftalmol ; 81: e0004, 2022. tab, graf
Article in Portuguese | LILACS | ID: biblio-1357124
RESUMO
RESUMO A acurácia do cálculo da lente intraocular não é perfeita, podendo ser comuns erros refrativos pós-operatórios, especialmente em pacientes submetidos à cirurgia refrativa prévia ou na presença de córneas assimétricas. O poder corneano após cirurgia refrativa pode ser medido com maior acurácia utilizando o mapa de poder óptico total na zona central de 4mm, com Orbscan II ou pelo mapa equivalent keratometric reading disponível no pentacam, com medidas centrais de 1,0, 2,0, 3,0 e 4,5mm. O objetivo desta série de casos é demonstrar a abordagem de quatro olhos em condições especiais corneanas, por meio do equivalent keratometric reading do pentacam para mensuração do poder corneano e o utilizando na biometria, em comparação com possíveis resultados obtidos com outras estratégias. Os quatro olhos foram submetidos a procedimentos refrativos prévios, e a lente intraocular escolhida a partir do uso do poder corneano calculado pelo equivalent keratometric reading mostrou excelentes resultados pós-operatórios.
ABSTRACT
ABSTRACT The accuracy of the intraocular lens calculation is not perfect, and postoperative refractive errors are common, especially in patients who have undergone previous refractive surgery or in presence of asymmetric corneas. Corneal power after refractive surgery can be more accurately measured using the total optical power map in the 4-mm central zone, by means of Orbscan II or equivalent keratometric reading map available on pentacam, with central measurements of 1.0, 2.0, 3.0 and 4.5 mm. The purpose of this case series is to demonstrate four approaches performed in special corneal conditions, using pentacam equivalent keratometric reading to measure corneal power and biometrics, and comparing with possible results obtained with other strategies. The four eyes were submitted to previous refractive procedures, and the intraocular lens chosen from the use of the corneal power calculated by equivalent keratometric reading showed excellent postoperative results.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Biometry / Lens Implantation, Intraocular / Refractive Surgical Procedures Type of study: Diagnostic study Limits: Aged / Female / Humans / Male Language: Portuguese Journal: Rev. bras. oftalmol Journal subject: Ophthalmology Year: 2022 Type: Article Affiliation country: Brazil Institution/Affiliation country: Ophthal Hospital Especializado/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Biometry / Lens Implantation, Intraocular / Refractive Surgical Procedures Type of study: Diagnostic study Limits: Aged / Female / Humans / Male Language: Portuguese Journal: Rev. bras. oftalmol Journal subject: Ophthalmology Year: 2022 Type: Article Affiliation country: Brazil Institution/Affiliation country: Ophthal Hospital Especializado/BR