Your browser doesn't support javascript.
loading
Estimulação do Ramo Esquerdo do Sistema His-Purkinje: Experiência Inicial / Left Bundle Branch Pacing of His-Purkinje Conduction System: Initial Experience
Forno, Alexander Romeno Janner Dal; Ternes, Caique M. P; Rech, João Vítor Ternes; Nascimento, Helcio Garcia; Lewandowski, Andrei; Damasceno, Grazyelle; dAvila, Andre.
  • Forno, Alexander Romeno Janner Dal; Hospital SOS Cardio. Florianópolis. BR
  • Ternes, Caique M. P; Hospital SOS Cardio. Florianópolis. BR
  • Rech, João Vítor Ternes; Hospital SOS Cardio. Florianópolis. BR
  • Nascimento, Helcio Garcia; Hospital SOS Cardio. Florianópolis. BR
  • Lewandowski, Andrei; Hospital SOS Cardio. Florianópolis. BR
  • Damasceno, Grazyelle; Hospital SOS Cardio. Florianópolis. BR
  • dAvila, Andre; Hospital SOS Cardio. Florianópolis. BR
Arq. bras. cardiol ; 118(2): 505-516, 2022. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1364318
RESUMO
Resumo Fundamento A estimulação ventricular direita convencional aumenta o risco de fibrilação atrial e insuficiência cardíaca em portadores de marca-passo. A estimulação do ramo esquerdo (RE) do sistema His-Purkinje pode evitar os desfechos indesejados da estimulação ventricular direita. Objetivo Analisar retrospectivamente os desfechos intraoperatórios, eletrocardiográficos e os dados clínicos do seguimento inicial de pacientes submetidos à estimulação do RE. Métodos Foram avaliados os parâmetros eletrônicos do implante e eventuais complicações precoces de 52 pacientes consecutivos submetidos à estimulação do sistema de condução. O nível de significância alfa adotado foi igual a 0,05. Resultados 52 pacientes foram submetidos a estimulação do RE do sistema His-Purkinje, obtendo sucesso em 50 procedimentos. 69,2% dos pacientes eram do sexo masculino e a mediana e intervalo interquatil da idade no momento do implante foi de 73,5 (65,0-80,0) anos. A duração do QRS pré-implante foi de 146 (104-175) ms e de 120 (112-130) ms após o procedimento. O tempo de ativação do ventrículo esquerdo foi de 78 (70-84) ms. A amplitude da onda R foi de 12,00 (7,95-15,30) mV, com limiar de estimulação de 0,5 (0,4-0,7) V × 0,4 ms e impedância de 676 (534-780) ohms. O tempo de procedimento foi de 116 (90-130) min e o tempo de fluoroscopia foi de 14,2 (10,0-21,6) min. Conclusão A estimulação cardíaca do sistema de condução His-Purkinje por meio da estimulação do ramo esquerdo é uma técnica segura e factível. Nesta casuística, apresentou alta taxa de sucesso, foi realizada com tempo de procedimento e fluoroscopia baixos e obteve medidas eletrônicas adequadas.
ABSTRACT
Abstract Background Conventional right ventricular pacing increases the risk of atrial fibrillation and heart failure in pacemaker patients. Stimulation of the left bundle branch (LBB) of the His-Purkinje system can prevent the unwanted outcomes of right ventricular pacing. Objective To retrospectively analyze the intraoperative outcomes, electrocardiographic and clinical data from the initial follow-up of patients submitted to stimulation of the LBB. Methods The electronic parameters of the implant and of possible early complications of 52 consecutive patients submitted to stimulation of the conduction system were evaluated. The adopted significance level was 0.05. Results Fifty-two patients underwent left bundle branch stimulation, with 50 successful procedures; 69.2% of the patients were male, and the median and interquartile range of age at the time of implantation was 73.5 (65.0-80.0) years. The pre-implant QRS duration was 146 (104-175) ms and 120 (112-130) ms after the procedure. The left ventricle activation time was 78 (70-84) ms. The R-wave amplitude was 12.00 (7.95-15.30) mV, with a stimulation threshold of 0.5 (0.4-0.7) V x 0.4 ms and impedance of 676 (534-780) ohms. The procedure duration was 116 (90-130) min, and the fluoroscopy time was 14.2 (10.0-21.6) min. Conclusion Cardiac stimulation of the His-Purkinje conduction system through the stimulation of the left bundle branch is a safe and feasible technique. In this study, it showed a high success rate, with low procedure and fluoroscopy periods, achieving adequate electronic measurements.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Bundle of His / Cardiac Pacing, Artificial Type of study: Observational study / Risk factors Limits: Humans / Male Language: English / Portuguese Journal: Arq. bras. cardiol Journal subject: Cardiology Year: 2022 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital SOS Cardio/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Bundle of His / Cardiac Pacing, Artificial Type of study: Observational study / Risk factors Limits: Humans / Male Language: English / Portuguese Journal: Arq. bras. cardiol Journal subject: Cardiology Year: 2022 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital SOS Cardio/BR