Your browser doesn't support javascript.
loading
Glucemia en ayunas entre 100 y 109 mg/dL versus prediabetes según hemoglobina glicosilada / Fasting blood glucose between 100 and 109 mg/dL versus prediabetes according to glycosylated hemoglobin
Chaila, María Zulema; Viniegra, Matías; Gabliardino, Juan José; Lucarelli, Carla; Maccallini, Gustavo; Frusti, Mauro; Elbarcha, Osvaldo; Louzan, Silvia; Salgado, Pablo; González, Claudio Daniel; Commendatore, Víctor Francisco.
  • Chaila, María Zulema; Centro de Análisis Clínicos y Especializados (CACE). San Miguel de Tucumán. AR
  • Viniegra, Matías; Laboratorio VZ. Ciudad Autónoma de Buenos Aires. AR
  • Gabliardino, Juan José; Centro de Endocrinología Experimental y Aplicada (CENEXA). La Plata. AR
  • Lucarelli, Carla; ACA Laboratorios. Bahía Blanca. AR
  • Maccallini, Gustavo; Laboratorio Hidalgo. Buenos Aires. AR
  • Frusti, Mauro; Baires Lab. Ciudad Autónoma de Buenos Aires. AR
  • Elbarcha, Osvaldo; Laboratorio LACE S. A. Córdoba. AR
  • Louzan, Silvia; Universidad Nacional de Córdoba. Córdoba. AR
  • Salgado, Pablo; Universidad de Buenos Aires. Ciudad Autónoma de Buenos Aires. AR
  • González, Claudio Daniel; Universidad Austral. Ciudad Autónoma de Buenos Aires. AR
  • Commendatore, Víctor Francisco; Universidad Nacional del Nordeste (UNNE). Entre Ríos. AR
Rev. Soc. Argent. Diabetes ; 56(2): 43-50, mayo - ago. 2022. ilus
Article in Spanish | LILACS, BINACIS | ID: biblio-1395840
RESUMEN

Introducción:

algunos estudios han señalado que valores de glucemia en ayunas entre 100 y 109 mg/dL se asocian con frecuencias elevadas de prediabetes cuando el criterio de clasificación son los valores de HbA1c. La Sociedad Argentina de Diabetes (SAD) sostiene a 110 mg/dL como valor a partir del cual se clasifica a un paciente como portador de glucemia en ayunas alterada; la frecuencia de individuos posiblemente clasificados en forma incorrecta, según este criterio, aún no se conoce en la población argentina.

Objetivos:

establecer la frecuencia con que se presenta prediabetes según HbA1c en una población sin diagnóstico de diabetes mellitus (DM) con glucemias en ayunas entre 100 y 109 mg/dL; correlacionar las dos variables y cuantificar la probabilidad de que esto ocurra respecto de otros con glucemias en ayunas <100 mg/dL. Materiales y

métodos:

se incluyeron 1.002 muestras de igual número de sujetos desde 45 laboratorios de análisis clínicos de la Asociación de Laboratorios de Alta Complejidad (ALAC), con procesamiento local de glucemia y centralizado de HbA1c por high performance liquid chromatography (HPLC). Análisis estadístico chi cuadrado, odds ratio, coeficiente de correlación y determinación de Pearson, y correlación serial de Durbin-Watson.

Resultados:

frecuencia de HbA1c ≥5,7% en la población estudiada con glucemias de ayunas entre 100 y 109 mg/dL=29,7%; test de chi cuadrado p<0,001; odds ratio de tener HbA1c ≥5,7% entre la población con glucemias en ayunas de 100 a 109 mg/dL vs aquella con valores <100 mg/dL=4,328 (IC 95% 2,922-6,411); r=0,852, r2 = 0,727, Durbin-Watson=1,152.

Conclusiones:

la prediabetes diagnosticada por HbA1c resultó cuatro veces más frecuente en la población estudiada con glucemias en ayunas entre 100 y 109 mg/dL, que en aquella con valores por debajo de 100 mg/dL.
ABSTRACT

Introduction:

some studies have shown that fasting blood glucose values between 100 and 109 mg/dL are associated with high rates of prediabetes when the classification criteria are HbA1c values. The Argentine Diabetes Society still maintains 110 mg/dL as the value from which a patient is classified as having impaired fasting blood glucose; the frequency of individuals possibly incorrectly classified, according to this criterion, is not yet known in any Argentine population.

Objectives:

to establish the frequency in a population without a diagnosis of diabetes mellitus with fasting blood glucose levels between 100 and 109 mg/dL in which prediabetes occurs according to HbA1c, to correlate both variables and to quantify the probability that this predicts with respect to others with fasting blood glucose levels <100 mg/dL. Materials and

methods:

1.002 samples from the same number of subjects from 45 clinical laboratories belonging to ALAC, with local processing of blood glucose and centralized processing of HbA1c by high performance liquid chromatography (HPLC). Statistical

analysis:

chi square, odds ratio, Pearson correlation coefficient, coefficient of determination and Durbin-Watson serial correlation.

Results:

frequency of HbA1c ≥5.7% in the studied population with fasting blood glucose levels between 100 and 109 mg/ dL = 29.7%, chi square test p<0.001; odds ratio of having HbA1c ≥5.7% between the population with fasting blood glucose levels of 100 to 109 mg/dL vs that one with values <100 mg/dL=4.328 (95% CI 2.922-6.411); r=0.852, r2 =0.727, DurbinWatson=1.152.

Conclusions:

prediabetes diagnosed by HbA1c was four times more frequent in the studied population with fasting glucose values between 100 and 109 mg/dL than in that one with values below 100 mg/dL.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Diabetes Mellitus Type of study: Prognostic study Language: Spanish Journal: Rev. Soc. Argent. Diabetes Journal subject: Endocrinology Year: 2022 Type: Article Affiliation country: Argentina Institution/Affiliation country: ACA Laboratorios/AR / Baires Lab/AR / Centro de Análisis Clínicos y Especializados (CACE)/AR / Centro de Endocrinología Experimental y Aplicada (CENEXA)/AR / Laboratorio Hidalgo/AR / Laboratorio LACE S. A/AR / Laboratorio VZ/AR / Universidad Austral/AR / Universidad Nacional de Córdoba/AR / Universidad Nacional del Nordeste (UNNE)/AR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Diabetes Mellitus Type of study: Prognostic study Language: Spanish Journal: Rev. Soc. Argent. Diabetes Journal subject: Endocrinology Year: 2022 Type: Article Affiliation country: Argentina Institution/Affiliation country: ACA Laboratorios/AR / Baires Lab/AR / Centro de Análisis Clínicos y Especializados (CACE)/AR / Centro de Endocrinología Experimental y Aplicada (CENEXA)/AR / Laboratorio Hidalgo/AR / Laboratorio LACE S. A/AR / Laboratorio VZ/AR / Universidad Austral/AR / Universidad Nacional de Córdoba/AR / Universidad Nacional del Nordeste (UNNE)/AR