Your browser doesn't support javascript.
loading
Evaluation of the Spies TM modalities image quality
Emiliani, Esteban; Talso, Michele; Baghdadi, Mohammed; Barreiro, Aarón; Orosa, Andrea; Serviàn, Pol; Gavrilov, Pavel; Proietti, Silvia; Traxer, Olivier.
  • Emiliani, Esteban; Université Pierre et Marie Curie. Hôpital Tenon. Department of Urology. Paris. FR
  • Talso, Michele; Université Pierre et Marie Curie. Hôpital Tenon. Department of Urology. Paris. FR
  • Baghdadi, Mohammed; Université Pierre et Marie Curie. Hôpital Tenon. Department of Urology. Paris. FR
  • Barreiro, Aarón; Université Pierre et Marie Curie. Hôpital Tenon. Department of Urology. Paris. FR
  • Orosa, Andrea; Université Pierre et Marie Curie. Hôpital Tenon. Department of Urology. Paris. FR
  • Serviàn, Pol; Université Pierre et Marie Curie. Hôpital Tenon. Department of Urology. Paris. FR
  • Gavrilov, Pavel; Université Pierre et Marie Curie. Hôpital Tenon. Department of Urology. Paris. FR
  • Proietti, Silvia; Université Pierre et Marie Curie. Hôpital Tenon. Department of Urology. Paris. FR
  • Traxer, Olivier; Université Pierre et Marie Curie. Hôpital Tenon. Department of Urology. Paris. FR
Int. braz. j. urol ; 43(3): 476-480, May.-June 2017. tab, graf
Article in English | LILACS | ID: biblio-840854
ABSTRACT
Introduction The Spies™ system (Karl-Storz®) was introduced into digital ureteroscopy to improve endoscopic vision. To date, there is no data to either indicate which of the Spies modalities is better for improving diagnosis and treatment procedures, nor to compare the modalities in terms of image quality. The aim of this study was to evaluate and compare the image quality of five Spies™ modalities (SM) to the standard white light in an in-vitro model. Materials and Methods Two standardized grids and 3 stones of different composition were recorded in white light and the 5SM (Clara, Chroma, Clara+Chroma), Spectra A and B) using 4 standardized aqueous scenarios. Twelve templates were done in order to simultaneously compare the same objective in the different modalities. Six urologists, five medical students, five urology residents, and five persons not involved with urology evaluated each video on a scale of 1 (very bad) to 5 (very good). Results Comparing white light to SM, subjects scored better the quality of Clara and Clara+Chroma than white light (p=0.0139 and p<0.05) and scored worse Spectra A and B (p=0.0005 and p=0.0023)). When comparing Clara to the other SM, it was ranked equivalent to Clara+Chroma (p=0.67) and obtained a higher rank than Chroma, Spectra A and B (p<0.05, p=0.0001 and p=0.0001). In the multivariate analysis mean scores were higher among urologists. Conclusion In all analyzed scenarios, the subjects ranked Clara and Clara+Chroma as the modalities with better image quality compared to white light.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Urologic Diseases / Ureteroscopy / Neoplasms Type of study: Evaluation studies / Prognostic study Limits: Adult / Female / Humans / Male Language: English Journal: Int. braz. j. urol Journal subject: Urology Year: 2017 Type: Article Affiliation country: France Institution/Affiliation country: Université Pierre et Marie Curie/FR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Urologic Diseases / Ureteroscopy / Neoplasms Type of study: Evaluation studies / Prognostic study Limits: Adult / Female / Humans / Male Language: English Journal: Int. braz. j. urol Journal subject: Urology Year: 2017 Type: Article Affiliation country: France Institution/Affiliation country: Université Pierre et Marie Curie/FR