Herramientas manuales vibrátiles y guantes anti-vibrátiles / Vibrating hand tools and anti-vibrating gloves
Quinchía, Rigoberto; Lizarazo S, César G; Saavedra Robinson, Luis A; Upegui Rincon, Sildrey; Guarguati Ariza, Juliana.
  • Quinchía, Rigoberto; Centro para la Prevención de Riesgos Profesionales. Medellín. CO
  • Lizarazo S, César G; Pontificia Universidad Javeriana. Departamento de Ingeniería Industrial. Bogotá. CO
  • Saavedra Robinson, Luis A; Pontificia Universidad Javeriana. Departamento de Ingeniería Industrial. Bogotá. CO
  • Upegui Rincon, Sildrey; Pontificia Universidad Javeriana. Departamento de Ingeniería Industrial. Bogotá. CO
  • Guarguati Ariza, Juliana; Pontificia Universidad Javeriana. Departamento de Ingeniería Industrial. Bogotá. CO
Cienc. Trab ; 20(63): 137-144, dic. 2018. tab, graf
Article in Spanish | LILACS | ID: biblio-984165
RESUMEN

OBJETIVO:

Determinar el impacto causado por el tipo de herramienta y tipo de guante sobre la transmisibilidad de la vibración mano-brazo.

MÉTODOS:

Se realizó un diseño experimental a trabajadores del sector de hidrocarburos, con el objetivo de identificar la transmisibilidad global de los guantes en diferentes actividades. Las mediciones se realizaron a través de dos acelerómetros uno instalado en la máquina y otro en la palma de la mano. La transmisibilidad fue calculada en el rango de frecuencias 0-2 kHz, para cinco tipos de herramientas y 3 tipos de guantes. Finalmente, se compararon los tiempos de exposición a los que puede estar expuesto el trabajador con el uso de los guantes.

RESULTADOS:

Se identificó la efectividad de los guantes para proteger a los operarios, permitiéndoles trabajar un mayor número de horas por día. El análisis estadístico evidencia que la variable tipo de herramienta tiene un efecto significativo sobre la transmisibilidad, mientras que el tipo de guante no presenta efecto estadístico alguno. El estudio presenta los porcentajes de aumento de tiempos de exposición y el estudio de las transmisibilidades.

CONCLUSIONES:

Los tres tipos de guantes evaluados mostraron tener un desempeño eficaz como atenuadores de la vibración. El aumento del tiempo de exposición permitido al usar guantes es muy significativo para todas las herramientas.
ABSTRACT

OBJECTIVE:

Determine the impact caused by the type of tool and type of glove on the transmissibility of the hand-arm vibration.

METHODS:

An experimental design was carried out for workers in the hydrocarbon sector, in order to identify the global transmissibility of gloves in different activities. The measurements were made through two accelerometers one installed in the machine and the other in the palm of the hand. The transmissibility was calculated in the fre quency range 0-2 kHz, for five types of tools and 3 types of gloves. Finally, the exposure times to which the worker may be exposed with the use of gloves were compared.

RESULTS:

The effectiveness of the gloves was identified to protect the workers, allowing them to work a greater number of hours per day. The statistical analysis shows that the variable type of tool has a significant effect on transmissibility, while the type of glove does not have any statistical effect. The study presents the percentages of increase in exposure times and the study of transmissibilities.

CONCLUSIONS:

The three types of gloves evaluated showed an effec tive performance as vibration attenuators. The increase of the expo sure time allowed when wearing gloves is very significant for all tools.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Vibration / Gloves, Protective / Hand-Arm Vibration Syndrome Type of study: Prognostic study Limits: Humans Language: Spanish Journal: Cienc. Trab Journal subject: Occupational Medicine / Public Health Year: 2018 Type: Article Affiliation country: Colombia Institution/Affiliation country: Centro para la Prevención de Riesgos Profesionales/CO / Pontificia Universidad Javeriana/CO

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Vibration / Gloves, Protective / Hand-Arm Vibration Syndrome Type of study: Prognostic study Limits: Humans Language: Spanish Journal: Cienc. Trab Journal subject: Occupational Medicine / Public Health Year: 2018 Type: Article Affiliation country: Colombia Institution/Affiliation country: Centro para la Prevención de Riesgos Profesionales/CO / Pontificia Universidad Javeriana/CO