A Case of Replacement of the Chronic Dissecting Descending Aortic Aneurysm after the Frozen Elephant Trunk Technique / 日本心臓血管外科学会雑誌
Japanese Journal of Cardiovascular Surgery ; : 316-319, 2017.
Article in Japanese | WPRIM | ID: wpr-379351
ABSTRACT
<p>A-54-year-old man with an extensive dissecting thoracic aortic aneurysm underwent staged surgery which consisted of preceding total aortic arch replacement with the frozen elephant trunk technique using J Graft Open Stent Graft, followed by open descending aorta repair. During the second operation, a Dacron graft was anastomosed directly to the stent graft and the true lumen thus, the true lumen could be preserved around the stent graft. We herein discuss our approach in this case, focusing on prevention of bleeding from the elephant trunk.</p>