Application of white blood cell differential in peripheral blood by flow cytometry / 中华检验医学杂志
Chinese Journal of Laboratory Medicine
; (12): 389-392, 2016.
Article
in Zh
| WPRIM
| ID: wpr-494292
Responsible library:
WPRO
ABSTRACT
Manual microscopic differential of white blood cell has been challenged by multiparameter flow cytometry,using monoclonal antibodies to define the different leukocyte types.Compared with manual differential,flow cytometry method is more sensitive,specific,objective and has good repeatability.Recent studies demonstrated flow cytometric differential correlates well with manual microscopic method and has good clinical performance for blast and immature granulocyte.Meanwhile more leukocyte populations can be identified with flow cytometric method,such as lymphocyte subset and CD 16 + monocyte,thus helping in monitoring blast in acute leukemia,B lymphocyte proliferative disorder differential diagnosis and minimal residual disease.With the development and improvement of flow cytometric differential,it might be a candidate reference method of leukocyte differential,gradually applied in the routine work.
Full text:
1
Index:
WPRIM
Type of study:
Guideline
Language:
Zh
Journal:
Chinese Journal of Laboratory Medicine
Year:
2016
Type: