Improvement of Determination of Aluminium in Water by Chrome Azurol S Spectrophotometry / 环境与健康杂志
Journal of Environment and Health
;
(12)1993.
Article
in Chinese
| WPRIM
| ID: wpr-536844
ABSTRACT
ve To improve the method of determination of aluminium in water. Methods The method of aluminium chrome azurol S-cetylpyridinium bromide spectrophotometry was used. Results The improved determi-nation of aluminium revealed perfect linear relationship in determining the standard aluminium solution series at the range of 0. 0-6.0?g/25 ml aluminium. The regression equation was calculated as y = 1. 031x + 0. 008(r=0.9994) . The detection limit was 0.02 mg/L aluminium. The coefficient variation was below 4.90% . The recovery rate ranged from 93.3% to 100.0% . Conclusion The improved method was rapid and easy to operate, suitable for determination of Al3+ in a large number of water samples.
Full text:
Available
Index:
WPRIM (Western Pacific)
Language:
Chinese
Journal:
Journal of Environment and Health
Year:
1993
Type:
Article
Similar
MEDLINE
...
LILACS
LIS