ABSTRACT
Objective To investigate the value of three-dimensional contrast-enhanced ultrasound (3D-CEUS) in diagnosing the hepatic artery complications after liver transplantation.Methods A total of 26 liver transplant donors or recipients suspected with hepatic artery complications were examined by color Doppler ultrasound, two-dimensional contrast-enhanced ultrasound ( 2D-CEUS ) and 3D-CEUS.The successful reconstruction rates of 3D-CEUS and the three-dimensional image quality of reconstructed hepatic arteries were evaluated.Results In the 26 patients, 21 hepatic arteries could be visualized with a successful reconstruction rate 81%.The three-dimensional images of hepatic arteries by 3D-CEUS were continuous.The coronal ( Z-axle) , fine or circuitous branches or tributaries could be visualized well.The segmental hepatic arteries origin could be determined and the spatial relationship of vessels could be visualized definitely.Conclusions The 3D-CEUS images are intuitive , three-dimensional and clear , and have clinical application value in diagnosing of hepatic artery complications after liver transplantation.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study Language: Chinese Journal: Organ Transplantation Year: 2014 Type: Article