Your browser doesn't support javascript.
loading
The value of MAGiC short T 1 inversion recovery sequence in the detection of bone marrow edema in sacroiliitis / 中华放射学杂志
Chinese Journal of Radiology ; (12): 59-63, 2021.
Article in Chinese | WPRIM | ID: wpr-884412
ABSTRACT

Objective:

To evaluate the value of MAGiC STIR sequence inassessing bone marrow edema (BME) of the sacroiliac joint (SIJ) in ankylosing spondylitis (AS) patients.

Methods:

Twenty two AS patients from the Affiliated Fifth Hospital of Sun Yat-sen University from September 2019 to January 2020 underwent MR scanning, consisting of T 2WI fat-suppressed (FS) sequence and MAGiC sequence. Each SIJ was divided into four quadrants for analysis on oblique coronal MR image. Two radiologists [middle-higher seniority levels (radiologist 1 and radiologist 2) reviewed image sets of two sequences [T 2WI FS and MAGiC short T 1 inversion recovery (STIR) sequence] independently at separate times, using Hermann-Braun scoring system for degree of BME and summing numbers of quadrants based on BME findings. Disagreements were resolved to reach an agreement for final results.Assessments were repeated two weeks later by radiologist 2. Intra-class correlation coefficients (ICC) were calculated to assess the inter-and intra-observer agreement for the degree of BME and numbers of positive BME quadrants in the MAGiC STIR sequence, respectively. The differences between the two sequences for the degree of BME and numbers of positive BME quadrants were analyzed with Wilcoxon signed-rank test and Chi-square test, respectively. Taking the results of T 2WI FS sequence as a reference standard, the ROC curve was drawn, sensitivity, specificity, positive predictive value and negative predictive value in the detection of BME were calculated for the MAGiC STIR sequence.

Results:

Nineteen AS patients including 38 sacroiliac joints were enrolled in our study, being divided into 152 quadrants. Inter-and intra-observer agreement for the degree of BME and inter-observer agreement for numbers of positive BME quadrants in the MAGiC STIR sequence were all good (ICC=0.936, 95%CI 0.912-0.953, P<0.001; ICC=0.910, 95%CI 0.878-0.934, P<0.001; ICC=0.876, 95%CI 0.833-0.909, P<0.001). The difference between the two sequences for the degree of BME in quadrants was statistically significant ( Z=-3.132, P=0.002). But there was no statistically significant difference between sequences for numbers of quadrants in detecting BME (χ2=0.244, P=0.622). Area under the ROC curve of MAGiC STIR sequence in diagnosis of BME was 0.920 ( P<0.001). Sensitivity, specificity, positive predictive value and negative predictive value for the MAGiC STIR sequence in the detection of BME were 82.0%, 95.1%, 89.1% and 91.5%, respectively.

Conclusion:

MAGiC STIR sequence can be used to evaluate bone marrow edema of SIJ in AS patients with high sensitivity and specificity.
Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study / Prognostic study Language: Chinese Journal: Chinese Journal of Radiology Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study / Prognostic study Language: Chinese Journal: Chinese Journal of Radiology Year: 2021 Type: Article