Your browser doesn't support javascript.
loading
Establishment of a blood concentration detection system for everolimus in recipients after liver transplantation / 器官移植
Organ Transplantation ; (6): 595-2021.
Article in Chinese | WPRIM | ID: wpr-886789
ABSTRACT
Objective To establish a detection system of ultra high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for everolimus concentration in whole blood of liver transplant recipients. Methods The proteins of samples were precipitated with methanol and zinc sulfate, and everolimus-D4 was used as the internal standard. Phenomenex Kinetex PFP column was used. The mobile phase A was water (containing 2 mmol/Lammonium formate and 0.1% formic acid), and the mobile phase B was methanol (containing 2 mmol/L ammonium formate and 0.1% formic acid). The gradient elution was performed with the flow rate of 1 mL/min, the column temperature of 50 ℃ and the injection volume of 1 μL. The multi-reaction monitoring mode was used to quantitatively analyze with electrospray positive ionization. The UPLC-MS/MS detection system required only 100 μL of whole blood, and could achieve a sufficient lower limit of quantification without complicated sample preparation. The total running time was within 4.5 min. Linear regression (1/x2) analysis was performed using peak area of everolimus / peak area of everolimus-D4 (y) and concentration of everolimus/concentration of everolimus-D4 (x) to calculate the calibration function and analyze its accuracy and linear relationship. UPLC-MS/MS was used to detect the trough blood concentration of everolimus in blood samples of 5 recipients after liver transplantation. Results The accuracy of quality control was within 15%, and the linear relationship of everolimus was good in the blood concentration range of 1-100 ng /mL(R2 > 0.990). Trough blood concentration of everolimus measured in blood samples of 5 liver transplant recipients ranged from 3.77 to 9.27 ng/mL. Conclusions The detection system of UPLC-MS/MS in this study is suitable for monitoring the concentration of everolimus in whole blood of liver transplant recipients because of its high accuracy, simple sample processing method and short detection time.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study Language: Chinese Journal: Organ Transplantation Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Diagnostic study Language: Chinese Journal: Organ Transplantation Year: 2021 Type: Article