Your browser doesn't support javascript.
loading
An automatic VMAT planning method for primary liver cancer radiotherapy based on predicting the feasibility DVH / 中华放射肿瘤学杂志
Chinese Journal of Radiation Oncology ; (6): 797-802, 2021.
Article in Chinese | WPRIM | ID: wpr-910471
ABSTRACT

Objective:

To establish an automatic planning method using volumetric-modulated arc therapy (VMAT) for primary liver cancer (PLC) radiotherapy based on predicting the feasibility dose-volume histogram (DVH) and evaluate its performance.

Methods:

Ten patients with PLC were randomly chosen in this retrospective study. Pinnacle Auto-Planning was used to design the VMAT automatic plan, and the feasibility DVH curve was obtained through the PlanIQ dose prediction, and the initial optimization objectives of the automatic plan were set according to the displayed feasible objectives interval. The plans were accessed according to dosimetric parameters of the planning target volume and organs at risk as well as the monitor units. All patients′ automatic plans were compared with clinically accepted manual plans by using the paired t-test.

Results:

There was no significant difference of the planning target volume D 2%, D 98%, D mean or homogeneity index between the automatic and manual plans ((58.55±2.81) Gy vs.(57.98±4.17) Gy, (47.15±1.58) Gy vs.(47.82±1.38) Gy, (53.14±0.95) Gy vs.(53.44±1.67) Gy and 1.15±0.05 vs. 1.14±0.07, all P>0.05). The planning target volume conformity index of the manual plan was slightly higher than that of the automatic plan (0.77±0.08 vs. 0.69±0.06, P<0.05). The mean doses of normal liver, V 30Gy, V 20Gy, V 10Gy, V 5Gy and V< 5Gy of the automatic plan were significantly better than those of the manual plan ((26.68±11.13)% vs.(28.00±10.95)%, (29.96±11.50)% vs.(31.89±11.51)%, (34.88±11.51)% vs.(38.66±11.67)%, (45.38±12.40)% vs.(50.74±13.56)%, and (628.52±191.80) cm 3vs.(563.15±188.39) cm 3, all P<0.05). The mean doses of the small intestine, the duodenum, and the heart, as well as lung V 10 of the automatic plan were significantly less than those of the manual plan ((1.83±2.17) Gy vs.(2.37±2.81) Gy, (9.15±9.36) Gy vs.(11.18±10.49) Gy, and (5.44±3.10) Gy vs.(6.25±3.26) Gy, as well as (12.70±7.08)% vs.(14.47±8.11)%, all P<0.05). Monitor units did not significantly differ between two plans ((710.67±163.72) MU vs.(707.53±155.89) MU, P>0.05).

Conclusions:

The automatic planning method using VMAT for PLC radiotherapy based on predicting the feasibility DVH enhances the quality for PLC plans, especially in terms of normal liver sparing. Besides, it also has advantages for the protection of the intestine, whole lung and heart.

Full text: Available Index: WPRIM (Western Pacific) Type of study: Practice guideline / Observational study / Prognostic study Language: Chinese Journal: Chinese Journal of Radiation Oncology Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Type of study: Practice guideline / Observational study / Prognostic study Language: Chinese Journal: Chinese Journal of Radiation Oncology Year: 2021 Type: Article