Your browser doesn't support javascript.
loading
Study of sub-region segmentation of brain metastases based on magnetic resonance perfusion imaging / 中华放射肿瘤学杂志
Chinese Journal of Radiation Oncology ; (6): 1047-1053, 2021.
Article in Chinese | WPRIM | ID: wpr-910512
ABSTRACT

Objective:

To evaluate the feasibility of magnetic resonance (MR) perfusion imaging for sub-region segmentation of brain metastases (BMs), and to provide reference for individualized radiotherapy based on blood flow perfusion heterogeneity in BMs patients.

Methods:

96 BMs patients were selected, including 55 patients with necrosis and 41 without necrosis. Each patient was scanned with CT simulation and MR simulation before radiotherapy. MIM Maestro 6.8.8 software was used to delineate the gross tumor volume (GTV) and necrosis GTV (GTV N) from enhanced T 1W images and T 2 Propeller images, respectively, and the solid GTV (GTV S) was obtained by the subtraction of the two. Then, the cerebral blood flow map of three dimensional arterial spin labeling (3D-ASL) was employed to determine the high perfused GTV (GTV H) and low perfused GTV (GTV L). The volume and proportion of sub-regions were counted and compared between two groups and the correlation of each sub-region was analyzed.

Results:

The volume of GTV in the necrosis and non-necrosis groups was 19.56 and 7.34 cm 3, respectively. Besides, the AUC of the ROC between GTV volume and necrosis was 0.749. In the necrosis group, the ratio of GTV N, GTV S, GTV H and GTV L to GTV was 20.47%, 79.53%, 33.03% and 46.50%, respectively (all P<0.05). Among them, the r value between GTV S and GTV was 0.963, 0.849 for GTV L and GTV, and 0.840 for GTV L and GTV S, significantly higher than 0.683 for GTV H and GTV and 0.764 for GTV H and GTV S (all P<0.05). In the non-necrosis group, the ratio of GTV H to GTV was higher than that in the necrosis group (58.95% vs. 33.03%, P<0.05). In addition, the ratio of GTV L to GTV was slightly lower than that in the necrosis group (41.05% vs. 46.50%, P>0.05). The r value between GTV H and GTV was 0.776, significantly higher than 0.574 between GTV L and GTV ( P<0.05).

Conclusion:

MR-3D-ASL can quantitatively analyze the heterogeneous blood perfusion of BMs, which could guide the sub-region segmentation and local dose escalation of tumors.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Radiation Oncology Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Radiation Oncology Year: 2021 Type: Article