Your browser doesn't support javascript.
loading
Treatment of acetabular both column fractures with integrated acetabular quadrilateral surface buttress plate / 中华骨科杂志
Chinese Journal of Orthopaedics ; (12): 1010-1017, 2021.
Article in Chinese | WPRIM | ID: wpr-910684
ABSTRACT

Objective:

To investigate the advantages and disadvantages and clinical effects of integrated acetabular quadrilateral surface buttress plate in the treatment of acetabular both column fractures.

Methods:

From September 2017 to March 2019, 14 patients with acetabular both column fractures were treated with integrated quadrilateral acetabular buttress plate and were followed up. The clinical data were retrospectively analyzed. There were 10 males and 4 females with an average age of 53.2 years (range, 26-75 years). Fracture classification were both column fractures according to the Letournel-Judet classification system, including 11 cases of combined posterior wall without posterior dislocation. The time from injury to operation was 8-19 days, with an average of 10.3 days. All operations were performed with a supra-ilioinguinal approach. After satisfactory reduction, the integrated acetabular quadrilateral surface buttress plate was used to fix the anterior and posterior column and quadrilateral fractures at the same time. After operation, Matta criteria was used to evaluate the quality of fracture reduction on postoperative images, and modified Merle d'Aubigné-Postel score to evaluate hip joint function.

Results:

The average operation time was 180 min (range, 120-320 min), and the intraoperative average blood loss was 980 ml (range, 700-1 600 ml). Operations were performed successfully with none intraoperative reshaping conducted, and the plate could fit into the bone surface well. All 14 patients were followed up with an average of 15.6 months (range, 9-20 months). During the follow-up, all fractures healed with an average of 3 months (range, 2.5-5 months). The reduction quality evaluated by the Matta criteria were 7 anatomical, 5 satisfactory, and 2 unsatisfactory, with an excellent and good rate of 85.7% (12/14). The hip joint function at the last follow-up was in accordance with the modified Merle d'Aubigné-Postel score was 12-18 points, with an average of 16.9 points, of which 8 excellent, 4 good, and 2 fair. The excellent and good function rate was 85.7% (12/14). During the operation, 1 patient had a rupture of about 1 cm of the peritoneum during the separation of the spermatic cord, which was immediately sutured and repaired. One patient had obturator nerve paralysis after the operation, without special treatment, and the paralysis symptoms were relieved during the 6th-month follow-up. There were no other operation-related complications.

Conclusion:

For both-column fractures characterized by central dislocation of the femoral head, the integrated acetabular quadrilateral buttress plate can simultaneously fix the anterior and posterior columns and quadrilateral surface at the same time. Satisfactory reduction and functional outcomes could be achieved by the novel plates.

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Orthopaedics Year: 2021 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: WPRIM (Western Pacific) Language: Chinese Journal: Chinese Journal of Orthopaedics Year: 2021 Type: Article