The value of synthetic MRI combined with field of view optimized and constrained undistorted single shot diffusion weighted imaging in differential diagnosis of BI-RADS 4 breast lesions / 实用放射学杂志
Article en Zh | WPRIM | ID: wpr-1020155
Biblioteca responsable: WPRO
ABSTRACT
Objective To evaluate the differential diagnostic value of synthetic magnetic resonance imaging(syMRI)and field of view optimized and constrained undistorted single shot diffusion weighted imaging(FOCUS DWI)in patient with breast imaging reporting and data system(BI-RADS)4 breast lesions.Methods A total of 68 patients who underwent breast MRI and were classified as BI-RADS category 4 were prospectively enrolled.Among them,there were 31 cases of benign lesions(benign group)and 37 cases of malignant lesions(malignant group).All patients underwent T1WI,T2WI,FOCUS DWI,dynamic contrast-enhanced magnetic resonance ima-ging(DCE-MRI)and syMRI.Two radiologists delineated the region of interest(ROI)on quantitative parameters images of syMRI and the apparent diffusion coefficient(ADC)images generated from FOCUS DWI and calculated T1,T2,proton density(PD)and ADC values,respectively.The thresholds and diagnostic efficacy of syMRI and FOCUS DWI parameters were evaluated by the receiver op-erating characteristic(ROC)curve.Logistic regression analysis was used to combine the parameters of the two sequences and evalu-ate the diagnostic efficacy.Results The T2,PD,and ADC values in the malignant group were significantly lower than those in the benign group(P<0.05),but there were no statistically significant difference in T1 values between the groups(P>0.05).T2 and ADC values could be used as important diagnostic indexes in patient with malignant lesions of BI-RADS 4 breast lesions,and the area under the curve(AUC)of T2 and ADC was 0.833 and 0.867,respec-tively.There was no significant difference in AUC of T2 and ADC between benign and malignant groups(Z=0.485,P=0.627).The AUC of T2 value combined with ADC value was 0.910,and the sensitivity and specificity was 90.3%and 89.2%,respectively.Conclusion T2 value of syMRI and ADC value of FOCUS DWI can be used as quantitative diagnostic indicators in patients with BI-RADS 4 breast lesions.The combination of T2 and ADC values can further improve the differential diagnosis efficiency.
Palabras clave
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Journal of Practical Radiology Año: 2024 Tipo del documento: Article
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Journal of Practical Radiology Año: 2024 Tipo del documento: Article