Adverse reactions of contrast-enhanced ultrasound and treatments of the adverse reactions / 中华超声影像学杂志
Chinese Journal of Ultrasonography
; (12): 885-887, 2010.
Article
en Zh
| WPRIM
| ID: wpr-386156
Biblioteca responsable:
WPRO
ABSTRACT
Objective To explore the adverse reactions of contrast-enhanced ultrasound and treatments of the adverse reactions. Methods 6035 patients examined by contrast-enhanced ultrasound were closely observed in the process and 20 minutes after the examination. The occurrence and clinical manifestations of adverse reactions were recorded. The patients were gave symptomatic treatments. Results Two of 6035 patients experienced mild adverse reactions related with contrast-enhanced ultrasound. The incidence rate was 0. 031% (2/6035). No moderate or serious adverse reaction occurred. The two patients recovered well after symptomatic treatments. Conclusions The contrast-enhanced ultrasound has high safety and low incidence rate of adverse reaction. Patients should be under close observation in the process of contrast-enhanced ultrasound. The symptomatic treatments should be gave in time.
Texto completo:
1
Índice:
WPRIM
Idioma:
Zh
Revista:
Chinese Journal of Ultrasonography
Año:
2010
Tipo del documento:
Article