Cardiac Resynchronization Therapy Device Implantation in a Patient with Cardiogenic Shock under Percutaneous Mechanical Circulatory Support
Korean Circulation Journal
; : 132-135, 2017.
Article
en En
| WPRIM
| ID: wpr-98366
Biblioteca responsable:
WPRO
ABSTRACT
65-year-old woman was admitted to our hospital with acute decompensated heart failure with reduced left ventricular ejection fraction and severe mitral regurgitation. Electrocardiography revealed a typical left bundle branch block and atrial fibrillation. Her condition deteriorated despite administering high-doses of inotropes and vasopressors. Pending a decision to therapy, venoarterial extracorporeal membrane oxygenation (ECMO) was performed when the patient underwent a cardiogenic shock. Although the hemodynamic status stabilized with ECMO support, weaning the patient from ECMO was not possible. Thus, we decided to perform cardiac resynchronization with defibrillator implantation as a “rescue” therapy. Five days post-implantation, the patient was successfully weaned from ECMO.
Palabras clave
Texto completo:
1
Índice:
WPRIM
Asunto principal:
Fibrilación Atrial
/
Choque Cardiogénico
/
Volumen Sistólico
/
Destete
/
Bloqueo de Rama
/
Oxigenación por Membrana Extracorpórea
/
Desfibriladores
/
Electrocardiografía
/
Terapia de Resincronización Cardíaca
/
Insuficiencia Cardíaca
Límite:
Aged
/
Female
/
Humans
Idioma:
En
Revista:
Korean Circulation Journal
Año:
2017
Tipo del documento:
Article