Validade e confiabilidade do questionário de avaliação multidimensional após o infarto do miocárdio / Validity and reliability of the dimensional assessment scale after myocardial infarction
Fiorin, Bruno Henrique,; Moreira, Rita Simone Lopes,; Luna Filho, Braulio,.
Affiliation
  • Fiorin, Bruno Henrique,; Universidade Federal do Espírito Santo. Vitória. BR
  • Moreira, Rita Simone Lopes,; Universidade Federal de São Paulo. São Paulo. BR
  • Luna Filho, Braulio,; Universidade Federal de São Paulo. São Paulo. BR
Rev. eletrônica enferm ; 22: 1-8, 2020.
Article de En, Pt | BDENF, LILACS | ID: biblio-1119144
Bibliothèque responsable: BR584.1
RESUMO
Objetivou-se avaliar as evidências de confiabilidade e a validade do questionário de Avaliação Multidimensional de Qualidade de Vida em pacientes após o infarto do miocárdio. Estudo metodológico. A confiabilidade foi verificada por meio da análise da consistência interna e pelo teste-reteste (α de Cronbach). A reprodutibilidade foi verificada com a avaliação intra e interexaminadores. A validade do instrumento foi calculada por meio da validade de constructo e critério através da validade convergente e concorrente. A amostra foi composta por 83 pacientes, sendo 51 pacientes internados e 32 ambulatoriais. Todos os domínios apresentam correlação significativa com escore geral. O questionário de Avaliação Multidimensional de Qualidade de Vida possui evidências de validade e confiabilidade em comparação ao questionário SF-36 com correlação de 0,89 (p<0,01). O Alfa de Cronbach obtido nos pacientes internados ambulatoriais foi de 0,85 e 0,83 respectivamente. O instrumento apresenta evidências de confiabilidade e validade para aplicação no Brasil em ambientes ambulatoriais e hospitalares.
ABSTRACT
The objective of this study was to evaluate the evidence of reliability and validity of the Multidimensional Quality of Life Assessment Scale in patients after acute myocardial infarction. Methodological study. Reliability was verified using internal consistency analysis and test-retest (Cronbach's α). Reproducibility was verified with intra- and inter-examiner assessment. The validity of the instrument was calculated using construct and criterion validity through convergent and concurrent validity. The sample consisted of 83 patients, of which 51 were hospitalized and 32 were receiving outpatient care. All the domains showed a significant correlation with overall score. The Multidimensional Quality of Life Assessment Scale showed evidence of validity and reliability compared to the SF-36 questionnaire, with a correlation of 0.89 (p<0.01). Cronbach's alpha for the inpatients and outpatients was 0.85 and 0.83, respectively. The instrument shows evidence of reliability and validity for application in outpatient and hospital settings in Brazil.
Sujet(s)
Mots clés

Texte intégral: 1 Indice: LILACS Sujet Principal: Qualité de vie / Infarctus du myocarde Limites du sujet: Humans langue: En / Pt Texte intégral: Rev. eletrônica enferm Thème du journal: ENFERMAGEM Année: 2020 Type: Article

Texte intégral: 1 Indice: LILACS Sujet Principal: Qualité de vie / Infarctus du myocarde Limites du sujet: Humans langue: En / Pt Texte intégral: Rev. eletrônica enferm Thème du journal: ENFERMAGEM Année: 2020 Type: Article