Podemos Acreditar no Ecocardiograma de Rotina para Avaliar o Ventrículo Direito e a Insuficiência Pulmonar? Um Estudo Comparativo com Ressonância Magnética Cardíaca / Can we Trust in Routine Echocardiography to Assess the Right Ventricle and Pulmonary Insufficiency? A Comparative Study with Cardiac Magnetic Resonance
Arq. bras. cardiol
; Arq. bras. cardiol;117(4): 690-698, Oct. 2021. tab, graf
Article
de En, Pt
| LILACS
| ID: biblio-1345226
Bibliothèque responsable:
BR1.1
RESUMO
Resumo Fundamento A ressonância magnética cardíaca (RMC) é o método de escolha para avaliar as dimensões e a função do ventrículo direito (VD), e a insuficiência pulmonar (IP). Objetivos Avaliar a acurácia da ecocardiografia bidimensional (ECO 2D) em estimar a função e as dimensões do VD e o grau de IP, e comparar os resultados obtidos pela ECO 2D com os da RMC. Métodos Comparamos os relatórios de ECO e RMC de pacientes cuja indicação para RMC havia sido para avaliar VD e IP. Um valor de p < 0,05 foi considerado estatisticamente significativo. Resultados Incluímos 51 pacientes com cardiopatia congênita com idade mediana de 9,3 anos (7-13,3 anos). Observou-se uma baixa concordância entre ECO 2D e RMC quanto à classificação da dimensão (Kappa 0,19; IC 95% 0,05 a 0,33, p 0,004) e da função do VD (Kappa 0,16; IC 95% -0,01 a +0,34; p 0,034). O tamanho do VD foi subestimado pela ECO 2D em 43% dos casos, e a função do VD foi superestimada pela ECO 2D em 29% dos casos. O grau de concordância entre os métodos quanto à classificação da IP não foi significativo (Kappa 0,014; IC 95% -0,03 a +0,06; p 0,27). Houve uma tendência de a ECO 2D superestimar o grau da IP. Conclusões A ECO 2D mostrou baixa concordância com a RMC quanto às dimensões e função do VD, e grau de IP. Em geral, a ECO subestimou as dimensões do VD e superestimou a função do VD e o grau de IP quando comparada à RMC.
ABSTRACT
Abstract Background Cardiac magnetic resonance (CMR) is the method of choice for assessing right ventricular (RV) dimensions and function, and pulmonary insufficiency (PI). Objectives To assess the accuracy of two-dimensional echocardiography (2D ECHO) in estimating RV function and dimensions, and the degree of PI, and compare the 2D ECHO and CMR findings. Methods We compared ECHO and CMR reports of patients whose indication for CMR had been to assess RV and PI. A p-value < 0.05 was considered statistically significant. Results We included 51 congenital heart disease patients, with a median age of 9.3 years (7-13.3 years). There was poor agreement between 2D ECHO and CMR for classification of the RV dimension (Kappa 0.19; 95% CI 0.05 to 0.33, p 0.004) and function (Kappa 0.16; 95% CI -0.01 to +0.34; p 0.034). The RV was undersized by 2D ECHO in 43% of the cases, and RV function was overestimated by ECHO in 29% of the cases. The degree of agreement between the methods in the classification of PI was not significant (Kappa 0.014; 95% CI -0.03 to +0.06, p 0.27). 2D ECHO tended to overestimate the degree of PI. Conclusions The 2D ECHO showed a low agreement with CMR regarding the RV dimensions and function, and degree of PI. In general, ECHO underestimated the dimensions of the RV and overestimated the function of the RV and the degree of PI as compared with CMR.
Mots clés
Cardiopatias Congênitas; Diagnostic, Imaging; Diagnóstico por Imagem; Echocardiography/methods; Ecocardiografia/métodos; Função Ventricular Direita; Heart Defects, Congenital; Imagem por Ressonância Magnética/métodos; Insuficiência Pulmonar; Lung Diseases; Magnetic Resonance, Imaging; Pneumopatias; Pulmonary Valve, Insufficiency; Ventricular Function, Right
Texte intégral:
1
Indice:
LILACS
Sujet Principal:
Dysfonction ventriculaire droite
/
Échocardiographie tridimensionnelle
/
Cardiopathies congénitales
Limites du sujet:
Child
/
Humans
langue:
En
/
Pt
Texte intégral:
Arq. bras. cardiol
Thème du journal:
CARDIOLOGIA
Année:
2021
Type:
Article