Revisión sobre el manejo de atresia de conducto auditivo externo mediante el uso de dispositivos auditivos implantables osteointegrados: a propósito de un caso exitoso con un implante Bonebridge® / Review of the management of external auditory canal atresia using osseo integrated implantable hearing devices: report of a successful case with Bonebridge® implant
Rev. otorrinolaringol. cir. cabeza cuello
; 74(2): 161-166, 2014. ilus
Article
de Es
| LILACS
| ID: lil-726168
Bibliothèque responsable:
CL1.1
RESUMEN
La atresia de conducto auditivo externo tiene una incidencia de 1 por 1.000 ó 2.000 nacidos vivos, predominantemente unilateral. Su manejo actual es controversial, en especial la cirugía de reconstrucción. En el último tiempo se han desarrollado dispositivos osteointegrados, que han revolucionado el tratamiento y cuestionado la indicación de cirugía. El liderazgo por un tiempo importante lo ha tenido el dispositivo tipo BAHA, pero que ha tenido problemas en el largo plazo, principalmente en relación con el tornillo del implante. En respuesta a estos problemas, se ha diseñado un nuevo implante osteointegrado de nombre Bonebridge®, con beneficios frente a su antecesor. Como en nuestro medio se tiene poca experiencia en este dispositivo se presenta una revisión a propósito de un caso clínico exitoso. El caso corresponde a un paciente de 18 años con hipoacusia de conducción máxima bilateral congénita, con diagnóstico de atresia de conducto auditivo externo bilateral, con inadecuada ganancia auditiva del cintillo óseo tradicional. Tanto la revisión bibliográfica como el caso clínico nos permiten aseverar que Bonebridge® corresponde a tratamiento adecuado en el manejo de la atresia del conducto auditivo externo, con ciertos beneficios sobre otros dispositivos y la cirugía.
ABSTRACT
The external auditory canal atresia has an incidence of 1 per 1000 or 2000 live births predominantly unilateral. Its management is controversial, especially with the decision of reconstructive surgery. Lately, have developed osseo integrated bone conduction devices, which have come to revolutionize the treatment and questioning the indication for surgery. The leadership for a long time its has had it the BAHA device type, but has several problems in long-term, mainly in relation to the screw used in the implant. In response to this problems, was designed a new osseo integrated implant named Bonebridge®, showing benefits over its predecessor. As in our setting there is little experience with this device, we present a review about a successful clinical case. The case is a patient of 18 years with a maximal bilateral hearing loss caused by a congenital bilateral atresia of the external auditory canal, and inadequate audition gain with traditional bone headband. As much the bibliographical overhaul as the clinical case allows to assert that Bone-bridge® corresponds to an alternative of treatment in the atresia of the external auditory canal and with certain benefits by on the other devices, as the surgery.
Mots clés
Texte intégral:
1
Indice:
LILACS
Sujet Principal:
Prothèses et implants
/
Conduction osseuse
/
Conduit auditif externe
/
Surdité de transmission
Type d'étude:
Etiology_studies
/
Prognostic_studies
Limites du sujet:
Adolescent
/
Humans
/
Male
langue:
Es
Texte intégral:
Rev. otorrinolaringol. cir. cabeza cuello
Thème du journal:
OTORRINOLARINGOLOGIA
Année:
2014
Type:
Article