Comparison of HIV Antibody Detection by Conventional Method and Dried Tube Specimen : Stability and Validation Study for HIV Serology.
Article
de En
| IMSEAR
| ID: sea-148403
This study was carried out to compare HIV antibody detection by conventional method and serum dried in test tube and to check the stability of dried tube specimen (DTS) at ambient temperature. A total of 50 serum samples were tested for HIV antibodies, which were sent for testing in the state reference laboratory, by conventional method according to NACO guidelines. The same serum samples were dried in test tubes and then after elution with PBS again tested for HIV antibodies by same method and kits at 0 day and after 30 days. DTS eluted by PBS showed linear correlation to the serum samples. The antibodies in DTS were found to be stable at 37o c up to 30 days. This method is simple, sensitive and specific and can be used in resource limited settings embarking on scaling up of HIV testing.
Texte intégral:
1
Indice:
IMSEAR
Type d'étude:
Diagnostic_studies
langue:
En
Année:
2011
Type:
Article