Ultrasonography in non-cirrhotic portal hypertension: correlation with splenoportography.
Article Dans En | IMSEAR | ID: sea-65067
ABSTRACT
Real time sonography followed by splenoportography was performed in 38 cases with non-cirrhotic portal hypertension. Eleven of these cases, in whom porto-systemic shunt surgery was done, were also evaluated by real time sonography post-operatively. The ultrasound findings correlated well in 37 cases (98%) with splenoportography. All the post-operative cases also revealed a patent portosystemic shunt on sonography. Ultrasonography, a valuable, non-invasive, initial investigation of portal hypertension, may thus be used as the only investigation to distinguish intra- from extra-hepatic obstruction and to evaluate patency of surgically created porto-systemic shunts. Invasive portography may be performed only if surgical treatment is anticipated.
Sujets)
Texte intégral: 1 Indice: IMSEAR Sujet Principal: Femelle / Humains / Mâle / Portographie / Anastomose chirurgicale portosystémique / Enfant / Enfant d'âge préscolaire / Échographie / Adolescent / Adulte Type d'étude: Diagnostic_studies langue: En Année: 1989 Type: Article