ABSTRACT
Intrauterine device(IUD)migrating to the bladder is rare,especially the migration far away from the uterus into the bladder wall.Due to no obvious clinical symptom in the early stage and being far away from the uterus,the IUD totally embedded in the bladder wall is prone to misdiagnosis and delay in treatment.We reported one case of such migration,aiming to improve the clinical management of the IUD totally embedded in the bladder wall.
Sujet(s)
Mots clés
Texte intégral: 1 Indice: WPRIM Sujet Principal: Pelvis / Utérus / Vessie urinaire / Dispositifs intra-utérins Limites du sujet: Female / Humans langue: Zh Texte intégral: Acta Academiae Medicinae Sinicae Année: 2023 Type: Article