Your browser doesn't support javascript.
loading
Effect and safety of common electric knife clamp coagulation technique in thyroidectomy in rabbits / 新乡医学院学报
Article Dans Zh | WPRIM | ID: wpr-1022674
Responsable en Bibliothèque : WPRO
ABSTRACT
Objective To investigate the effect and safety of common electric knife clamp coagulation technique in rabbit thyroidectomy.Methods According to the random number table method,12 New Zealand rabbits were divided into the clamp coagulation group and the ultrasonic scalpel group,with 6 rabbits in each group.The middle part of the thyroid gland in the clamp coagulation group was severed by common electric knife clamp coagulation,while that in the ultrasonic scalpel group was severed by ultrasonic scalpel electrocoagulation.The postoperative conditions of rabbits in the two groups were observ.The severed thyroid tissue was stained with hematoxylin-eosin(HE),and its histopathology after thermal damage was observed under the light microscope.The scope of thermal damage was determined.On the 1st,3rd and 7th day after operation,the auricular venous blood of all rabbits was collected to assess the serum interleukin-6(IL-6)and C-reactive protein(CRP)levels by enzyme-linked immunosorbent assay.The rabbits were killed on the 7th day after operation,and the residual thyroid glands were removed and stained by HE.The pathological changes and inflammatory cell infiltration were observed under the light microscope.Results The rabbits in the 2 groups survived well after operation,and the operative area healed well.No obvious effusion,blood clot,bleeding,incision infection or other complications were found in the residual cavity.Under the light microscope,the surface of the incisal margin of the thyroid gland showed obvious lesions.In the injured area,some cell structures were damaged with coagulated necrosis,some follicles were ruptured,and the contents inside were solidly concentrated and deeply stained.The cytoplasmic eosinophils in parafollicular cells increased,and nuclear pyknosis,fragmentation,and even dissolution occurred.The thermal damage ranges of thyroid tissues in the ultrasonic scalpel and clamp coagulation groups were(0.72± 0.10)mm and(0.88±0.11)mm,respectively.The range of thermal damage in the clamp coagulation group was significantly greater than that in the ultrasonic scalpel group(t=-2.740,P<0.05).On the 1st,3rd and 7th day after surgery,there was no significant difference in the levels of serum CRP and IL-6 between the two groups(P>0.05).The serum IL-6 levels in both groups on the 3rd and 7th day after surgery were significantly higher than those on the 1st day after surgery(P<0.05).There was no significant difference in serum IL-6 level on the 3rd and 7rd day after surgery in the two groups(P>0.05).Thyroid follicular atrophy,glia reduction,follicular epithelial hyperplasia,collagenization and hyperplasia of interstitial fibers were observed in the residual thyroid sections of both groups.No obvious inflammatory cell infiltration was observed.Conclusion In rabbit thyroidectomy,it is safe to remove the thyroid gland using the common electric knife clamp coagulation technique.In terms of preventing thermal damage,the ultrasonic scalpel is better than the common electric knife clamp coagulation technique,but the thermal damage to thyroid tissues caused by the common electric knife clamp coagulation technique is within the safe operating range.

Texte intégral: 1 Indice: WPRIM langue: Zh Texte intégral: Journal of Xinxiang Medical College Année: 2024 Type: Article
Texte intégral: 1 Indice: WPRIM langue: Zh Texte intégral: Journal of Xinxiang Medical College Année: 2024 Type: Article