Your browser doesn't support javascript.
loading
Delayed Rupture of Flexor Pollicis Longus after Volar Plating for a Distal Radius Fracture
Article Dans En | WPRIM | ID: wpr-15279
Responsable en Bibliothèque : WPRO
ABSTRACT
Although extensor tendon rupture often occurs after volar plating for a distal radius fracture, a flexor tendon rupture is extremely rare. Most reported instances of flexor tendon ruptures after volar plating have involved improper placement of the plate, increased prominence of the distal edge of the plate because of collapse of the fracture site, use of custom-made plates, current steroid use by the patient, or a history of tendon injury. We report a case of delayed rupture of the flexor pollicis longus tendon 40 months after volar plating with a 3.5-mm T-locking compression plate for which the distal edge was located at the transverse ridge level of the distal radius. If symptoms such as tendon irritation occur in this situation, surgeons should consider removing the plate as soon as possible after bony union is achieved.
Sujets)

Texte intégral: 1 Indice: WPRIM Sujet Principal: Fractures du radius / Rupture / Traumatismes des tendons / Pouce / Plaques orthopédiques / Ostéosynthèse interne Limites du sujet: Female / Humans langue: En Texte intégral: Clinics in Orthopedic Surgery Année: 2012 Type: Article