Your browser doesn't support javascript.
loading
Endoscopic Electrosurgery in Patients with Cardiac Implantable Electronic Devices
Clinical Endoscopy ; : 176-181, 2016.
Article de En | WPRIM | ID: wpr-211324
Bibliothèque responsable: WPRO
ABSTRACT
BACKGROUND/AIMS: Patients with cardiac implantable electronic devices (CIEDs) undergoing endoscopic electrosurgery (EE) are at a risk of electromagnetic interference (EMI). We aimed to analyze the effects of EE in CIED patients. METHODS: Patients with CIED who underwent EE procedures such as snare polypectomy, endoscopic submucosal dissection (ESD), and endoscopic retrograde cholangiopancreatography (ERCP) with endoscopic sphincterotomy (EST) were retrospectively analyzed. Postprocedural symptoms as well as demographic and outpatient follow-up data were reviewed through medical records. Electrical data, including preprocedural and postprocedural arrhythmia records, were reviewed through pacemaker interrogation, 24-hour Holter monitoring, or electrocardiogram. RESULTS: Fifty-nine procedures in 49 patients were analyzed. Fifty procedures were performed in 43 patients with a pacemaker, and nine were performed in six patients with an implantable cardioverter-defibrillator. There were one gastric and 44 colon snare polypectomies, five gastric and one colon ESDs, and eight ERCPs with EST. Fifty-five cases of electrical follow-up were noted, with two postprocedural changes not caused by EE. Thirty-one pacemaker interrogations had procedure recordings, with two cases of asymptomatic tachycardia. All patients were asymptomatic with no adverse events. CONCLUSIONS: Our study reports no adverse events from EE in patients with CIED, suggesting that this procedure is safe. However, because of the possibility of EMI, recommendations on EE should be followed.
Sujet(s)
Mots clés
Texte intégral: 1 Indice: WPRIM Sujet Principal: Patients en consultation externe / Troubles du rythme cardiaque / Tachycardie / Dossiers médicaux / Études rétrospectives / Études de suivi / Cholangiopancréatographie rétrograde endoscopique / Électrocardiographie ambulatoire / Sphinctérotomie endoscopique / Défibrillateurs implantables Type d'étude: Observational_studies / Prognostic_studies / Risk_factors_studies Limites du sujet: Humans langue: En Texte intégral: Clinical Endoscopy Année: 2016 Type: Article
Texte intégral: 1 Indice: WPRIM Sujet Principal: Patients en consultation externe / Troubles du rythme cardiaque / Tachycardie / Dossiers médicaux / Études rétrospectives / Études de suivi / Cholangiopancréatographie rétrograde endoscopique / Électrocardiographie ambulatoire / Sphinctérotomie endoscopique / Défibrillateurs implantables Type d'étude: Observational_studies / Prognostic_studies / Risk_factors_studies Limites du sujet: Humans langue: En Texte intégral: Clinical Endoscopy Année: 2016 Type: Article