Numerical expression of volume status using the bioimpedance ratio in continuous ambulatory peritoneal dialysis patients: A pilot study
Article de En | WPRIM | ID: wpr-218947
Bibliothèque responsable: WPRO
ABSTRACT
BACKGROUND: Volume overload results in higher mortality rates in patients on continuous ambulatory peritoneal dialysis (CAPD). The ratio of bioimpedance (RBI) might be a helpful parameter in adjusting dry body weight in CAPD patients. This study examined whether it is possible to distinguish between non-hypervolemic status and hypervolemic status in CAPD patients by using only RBI. METHODS: RBI was calculated as follows: RBI = impedance at 50 kHz/impedance at 500 kHz. Based on the experts’ judgements, a total of 64 CAPD patients were divided into two groups, a non-hypervolemic group and a hypervolemic group. The RBI was measured from right wrist to right ankle (rw-raRBI) by bioimpedance spectroscopy (BCM®, Fresenius Medical Care) before and after the peritosol was emptied. Other RBIs were measured from the right side of the anterior superior iliac spine to the ipsilateral ankle (rasis-raRBI) to control for the electro-physiological effects of peritoneal dialysate. RESULTS: The mean rw-raRBI of non-hypervolemic patients was higher than that of hypervolemic patients in the presence (1.141 ± 0.022 vs. 1.121 ± 0.021, P < 0.001) of a peritosol. Likewise, the mean rasis-raRBI of non-hypervolemic patients was higher than that of hypervolemic patients (presence of peritosol: 1.136 ± 0.026 vs. 1.109 ± 0.022, P < 0.001; absence of peritosol: 1.131 ± 0.022 vs. 1.107 ± 0.022, P < 0.001). CONCLUSION: The volume status of CAPD patients was able to be simply expressed by RBI. Therefore, this study suggests that when patients cannot be analyzed using BCM, RBI could be an alternative.
Sujet(s)
Mots clés
Texte intégral: 1 Indice: WPRIM Sujet Principal: Analyse spectrale / Rachis / Poignet / Poids / Projets pilotes / Mortalité / Dialyse péritonéale / Dialyse péritonéale continue ambulatoire / Impédance électrique / Cheville Type d'étude: Prognostic_studies Limites du sujet: Humans langue: En Texte intégral: Kidney Research and Clinical Practice Année: 2017 Type: Article
Texte intégral: 1 Indice: WPRIM Sujet Principal: Analyse spectrale / Rachis / Poignet / Poids / Projets pilotes / Mortalité / Dialyse péritonéale / Dialyse péritonéale continue ambulatoire / Impédance électrique / Cheville Type d'étude: Prognostic_studies Limites du sujet: Humans langue: En Texte intégral: Kidney Research and Clinical Practice Année: 2017 Type: Article