Primary Repair of Traumatic Aortic Transection with Clamp and Sew Technique: Report of 2 cases / 대한흉부외과학회지
The Korean Journal of Thoracic and Cardiovascular Surgery
; : 756-760, 2000.
Article
de Ko
| WPRIM
| ID: wpr-224644
Bibliothèque responsable:
WPRO
ABSTRACT
Traumatic aortic transection after blunt chest injury is highly lethal and has high operative mortality. Recently, the diagnostic and therapeutic method of this injury is advanced, especially in spinal cord protection during aortic cross-clamping. We have experienced two cases of traumatic aortic transection with left hemothorax after blunt chest injury, which was diagnosed in operative field. The transected aorta was primarily repaired with clamp and sew method and postoperative paraplegia had not occured. The patients were dischraged without any significant complications. We report these cases with a review of literature.