The HRCT Scan of Normal Middle-inner Ear / 实用放射学杂志
Journal of Practical Radiology
; (12): 339-342, 2001.
Article
de Zh
| WPRIM
| ID: wpr-410316
Bibliothèque responsable:
WPRO
ABSTRACT
Objective To study the scan technique that can completely demonstrate the structures of middle-inner ear.Methods Ninety volunteers underwent 30° axial and 105° coronal HRCT scan.The manifestations of the ministructures of middle-inner ear were observed and their demonstration rate was calculated.The demonstration of different structures of middle-inner ear was evaluated and compared on HRCT.Results (1)The scan planes of 30° axial and 105° coronal were correspondent to some structures of middle-inner ear and could completely demonstrate them.(2)30° axial and 105° coronal HRCT scan had their own advantages respectively in demonstrating the structures of middle-inner ear.Conclusion The technique of 30° axial and 105° coronal HRCT scan of middle-inner ear is useful in demonstrating the structures,including the nerve,joint,ligament etc and the relationship among them.
Texte intégral:
1
Indice:
WPRIM
langue:
Zh
Texte intégral:
Journal of Practical Radiology
Année:
2001
Type:
Article