Your browser doesn't support javascript.
loading
A Gaseous Benzene and Trimethylamine Sensor Based on Cross Sensitivity on Nano-Zr3 Y2 O9 / 分析化学
Article de Zh | WPRIM | ID: wpr-452338
Bibliothèque responsable: WPRO
ABSTRACT
A novel method based on cross sensitivity of cataluminescence (CTL) generated on the surface of a nanometer composite oxide was proposed for simultaneous determination of benzene and trimethylamine (TMA) in air. A variety of nanometer composite oxides based on Y2 O3 that showed catalytic activity to many gas molecules were synthesized. For the fabrication of the detector, nanometer composite oxide was directly coated on the ceramic rod to form a 0. 1-0. 15 mm thick layer. The ceramic rod with nanometer composite oxide was inserted into a quartz tube with an inner diameter of 10 mm. The temperature of nanometer composite oxide was controlled by the digital heater. When gas samples passed through the nanometer composite oxide in the quartz tube by the air flow, the CTL was generated during the catalytic oxidation on the surface of the nanometer composite oxide. The CTL signals were respectively recorded by two ultra weak chemiluminescence analyzers. The CTL intensity and selectivity for the determination of benzene and TMA on nano- Zr3 Y2 O9 which was characterized by TEM were bigger and better than those on other nanosized composite oxides. The optimum experimental conditions were tested. Selective determination was achieved at a wavelength of 440 nm for benzene and 540 nm for TMA. The surface temperature of the nanometer materials was about 313 ℃. The flow rate of air carrier was about 140 mL/ min. The limit of detection of this method was 0. 30 mg / m3 for benzene at 440 nm and 0. 70 mg / m3 for TMA at 540 nm. The linear range of CTL intensity versus concentration of benzene at 440 nm was 0. 8-105. 0 mg / m3 , benzene at 540 nm was 3. 0-130. 0 mg / m3 , TMA at 440 nm was 2. 5-232. 0 mg / m3 and TMA at 540 nm was 1. 2-156. 0 mg / m3 . The recovery of 5 testing standard samples by this method was 96. 8% -102. 3% for benzene and 97. 6% -103. 4%for TMA. Common coexistence matters, such as formaldehyde, ethanol, acetone, ammonia, sulfur dioxide and carbon dioxide, did not disturb the determination. The relative standard deviation (RSD) of CTL signals of a continuous 200 h detection of gas mixture of 50 mg / m3 benzene and 50 mg / m3 TMA was 2. 0% , which demonstrated the longevity and steady performance of nano-Zr3 Y2 O9 to benzene and TMA under this experimental conditions.
Mots clés
Texte intégral: 1 Indice: WPRIM Type d'étude: Diagnostic_studies langue: Zh Texte intégral: Chinese Journal of Analytical Chemistry Année: 2014 Type: Article
Texte intégral: 1 Indice: WPRIM Type d'étude: Diagnostic_studies langue: Zh Texte intégral: Chinese Journal of Analytical Chemistry Année: 2014 Type: Article