Your browser doesn't support javascript.
loading
Research on the geometric difference between different ITV generation methods in non-small cell lung cancer treated with stereotactic radiotherapy / 中华放射肿瘤学杂志
Article de Zh | WPRIM | ID: wpr-481671
Bibliothèque responsable: WPRO
ABSTRACT
Objective To study the geometric difference between six different ITV generation methods from 4DCT for patients with non?small cell lung cancer ( NSCLC) treated with stereotactic ablative radiotherapy technique ( SABR) . Methods Between Dec. 2013 and Mar. 2014,16 patients were enrolled in this retrospective study. All patients underwent imaging with 4DCT scans. The MI and DI index were evaluated between six ITV generation methods:combining GTV from all 10 respiratory phases ( ITV10 );combining GTV from four respiratory phases, including two extreme phases ( 0% and 50%) plus two intermediate phases ( 20% and 70%) ( ITVYeo ) which was proposed by Seung?Gu Yeo of Soonchunhyang University;combining GTV from two extreme phases ( ITVEI+EE ) . And combining GTV from five odd phases (10%,30%,50%,70%,90%)(ITVodd).Accordingly the ITVEVEN which was combined from the remaining five even phases (20%,40%,60%,80%,0%),and ITVAVG,ITVMIP were contoured from two reconstructed 4DCT sequences,finally,a method which was not sensitive to the tumor volume and motion characteristic was selected for clinical use. Data were compared using a variance analysis followed by Student?Newman?Keulsa test both in same group or between groups. At the same time, the volume and the three dimensional movements of the tumor, the relativity of MI and DI were analyzed by Multi?parameter regression analysis. Results The mean (range) tumor motion (RLR,RAP,RCC,and R3D) are 3. 5 mm (1. 4?8. 4 mm),4. 5 mm (1. 1?8. 6 mm),9. 5 mm (0?10 mm),12. 3 mm (2. 5?55. 3 mm) respectively. The IGTVx volume are Underestimated by 25. 7%,35. 6%,17. 9%,12. 8%,3. 6%,4. 8%( P=0. 000) respectively. The MI index comparisons between six ITV generation methods and ITV10 showed statistical significance:0. 69,0. 62,0. 80, 0. 86,0. 93,0. 91 ( P=0. 006 ) . The DI index showed no statistical significance:0. 98, 0. 98, 0. 97, 0. 97, 0. 99,0. 98(P=0. 130).The tumor size and motion amplitude were certified not the independent factors for the MI index of ITVodd and ITVEVEN . Conclusions IGTVODD/EVEN based on odd or even 4DCT phases is not sensitive to the tumor size or motion characteristic and is proved to have a good marching with ITV10 meanwhile maintaining a reasonable contouring efficiency,it can be recommend to the institutions which was not equipped with the deformable registration systems.
Mots clés
Texte intégral: 1 Indice: WPRIM Type d'étude: Observational_studies langue: Zh Texte intégral: Chinese Journal of Radiation Oncology Année: 2015 Type: Article
Texte intégral: 1 Indice: WPRIM Type d'étude: Observational_studies langue: Zh Texte intégral: Chinese Journal of Radiation Oncology Année: 2015 Type: Article