Tracheobronchial Rupture during Double-lumen Endobronchial Tube Insertion for One-lung Ventilation: 2 cases / 대한마취과학회지
Korean Journal of Anesthesiology
; : 1149-1152, 1999.
Article
de Ko
| WPRIM
| ID: wpr-55490
Bibliothèque responsable:
WPRO
ABSTRACT
A number of complications during the use of double-lumen endobronchial tubes are reported, specifically tracheobronchial rupture, a rare but serious complication. Risk factors associated with tracheobronchial rupture include inexperienced endoscopists, intubating stylets, multiple vigorous attempts at intubation, overdistension of the tracheal or bronchial cuff with high pressure, position change with an inflated cuff, and anatomical abnormality. We report 2 cases of tracheobronchial rupture which occurred during the use of double-lumen endobronchial tubes.
Mots clés
Texte intégral:
1
Indice:
WPRIM
Sujet Principal:
Rupture
/
Facteurs de risque
/
Ventilation sur poumon unique
/
Intubation
Type d'étude:
Etiology_studies
/
Risk_factors_studies