Your browser doesn't support javascript.
loading
Verification and Evaluation on Microbial Limit Test of Methodology for Changyanning Tablets in ChP 2015 / 中国药师
China Pharmacist ; (12): 946-948, 2017.
Article Dans Zh | WPRIM | ID: wpr-610149
Responsable en Bibliothèque : WPRO
ABSTRACT

Objective:

To provide a method of microbial limit test for Changyanning tablets and carry out the verification of the mothod.

Methods:

A plate method was used in the total aerobic microbial count and the concentration of the test liquid was 1∶100.A plate method was used in the total yeast and mold count while the concentration of the test liquid was 1∶10.The direct inoculation method was used for the detection of Escherichia coli,bile-tolerant gram-negative bacteria and Salmonella enterica subsp.

Results:

The recoveries of the five strains were from 0.5 to 2.0.

Conclusion:

The method is suitable for the microbial limit examination of Changyanning tablets.

Texte intégral: 1 Indice: WPRIM langue: Zh Texte intégral: China Pharmacist Année: 2017 Type: Article
Texte intégral: 1 Indice: WPRIM langue: Zh Texte intégral: China Pharmacist Année: 2017 Type: Article