Your browser doesn't support javascript.
loading
The design and clinical application of a new type of disposable heparin free dialysis tube / 中国实用护理杂志
Article de Zh | WPRIM | ID: wpr-620375
Bibliothèque responsable: WPRO
ABSTRACT
Objective To investigate the clinical effect of a new type of disposable heparin freedialysis tube in uremic patients without heparin dialysis. Methods A total of 110 patients withoutheparin dialysis were divided into control group and observation group by random digits table method with55 cases each. Based on the same pre dialysis and dialysis for heparin saline flushing of discontinuoussaline on the control group using the traditional dialysis pipe for hemodialysis without heparin, theobservation group used disposable non heparin dialysis pipe for hemodialysis without heparin. The numberof patients with venous catheter blockage, blood loss and completion of dialysis time in two groups wasrecorded. Results The number of patients with venous catheter blockage, blood loss and completion ofdialysis time was 6, 6, 47 cases in control group and 0, 0, 54 cases in observation group. The differences were statistically significant (χ2=4.407, 4.407, 4.356, P<0.05). Conclusions The new disposableheparin free dialysis tube can reduce the loss of blood and prolong the treatment time, and the operation issimple, safe and effective, and has good application value and application prospect.
Mots clés
Texte intégral: 1 Indice: WPRIM langue: Zh Texte intégral: Chinese Journal of Practical Nursing Année: 2017 Type: Article